Code
SNT-TC-1A: how NDT technicians are certified in the US.
The recommended practice most US employers use to train, examine, and certify their own NDT technicians at Level I, II, and III.
What it covers
SNT-TC-1A in plain terms.
SNT-TC-1A is the backbone of NDT certification in the US. It isn't a law or a code: it's a recommended practice that an employer turns into its own written practice, which then governs how that employer trains, examines, and certifies its technicians.
It sets three levels. Level I does specific tests under supervision. Level II sets up and calibrates equipment, performs tests and interprets results against the code. Level III writes procedures, interprets codes, and certifies and oversees the others.
Certification needs recommended hours of training and experience in each method, a vision test, and written general, specific, and practical exams. The employer's Level III, or an outside agency, administers them.
Certification belongs to the employer. When a technician changes companies, the new employer certifies them again under its own written practice.
In the glossary: Employer-based and central certification · Level I, II, and III · Written practice
- Full title
- Personnel Qualification and Certification in Nondestructive Testing
- Issued by
- American Society for Nondestructive Testing (ASNT)
- Type
- Recommended practice: guidelines an employer adopts in its own written practice
- Who certifies
- The employer, not ASNT or a third party
- Levels
- Level I, Level II, Level III
- Called for by
- ASME, API, AWS, and many contract specifications
- Stricter alternative
- ANSI/ASNT CP-189, a standard rather than a recommended practice
- Central alternatives
- ISO 9712 internationally; CAN/CGSB-48.9712 in Canada
Who it's for
One record. Both sides of the job.
How inspection works
Methods under SNT-TC-1A.
Who sets the procedure, who sets acceptance, and who may do the work, method by method.
| Method | Procedure | Acceptance | Certification |
|---|---|---|---|
| Every NDT method | The employer's written practice, method by method | Not an acceptance standard | Level I, II, or III per method |
Acceptance criteria
How a weld passes or fails.
SNT-TC-1A doesn't judge welds. It decides who is allowed to judge them, and that decides whether a report counts.
- A report is only valid if the person who interpreted the results is certified, at Level II or III, in that method.
- Certification is method by method. A Level II in radiography isn't a Level II in ultrasonic testing.
- Vision is tested every year; a lapsed vision test lapses the certification.
- Certifications expire and have to be renewed under the written practice.
- The written practice can be stricter than SNT-TC-1A, and the customer's code can add to it.
That's why a report carries the technician's name, method, level, and signature: the reviewer has to be able to check them against the employer's records.
A summary, not the code. Limits and exceptions are in the edition your job works to.
The report
What a report has to show about who did the work.
The fields a Level III checks before signing. Miss one and the report comes back.
- Technician name and signature
- Method and certification level for the method used
- Certification number or reference, and its expiry
- The employer whose written practice it falls under
- Reviewer name, level, and sign-off
Where reports go wrong
The SNT-TC-1A mistakes that send a report back.
How the job's procedures come from your plan
The NDT reporting checklist: eight ways to get reports right the first time
The right person, the wrong method.
A Level II in one method interprets results in another. The report looks complete and isn't valid.
Expired certification or vision test.
The certification lapsed between jobs and nobody noticed until the audit.
Certification carried between employers.
A new hire's old certificate doesn't count until the new employer certifies them under its own practice.
Missing certification records.
Missing signatures and certification records are among the common findings when the Navy audits inspection work.
Related codes
The codes around it.
From the blog: Human reliability in NDT
FAQ
Questions.
Every other answer is on the FAQ page.
What is SNT-TC-1A?
A recommended practice from ASNT that employers use to set up their own written practice for training, examining, and certifying NDT personnel at Level I, II, and III.
Who certifies a technician under SNT-TC-1A?
The employer. ASNT publishes the practice, but certification is issued by the employer under its written practice, often through its Level III.
What's the difference between SNT-TC-1A and CP-189?
SNT-TC-1A is a recommended practice that employers adapt. ANSI/ASNT CP-189 is a standard with mandatory requirements, and is stricter.
Does SNT-TC-1A certification transfer between employers?
No. Each employer certifies its own people. A new employer has to certify a technician under its own written practice.
Is SNT-TC-1A used in Canada?
Canadian codes usually require central certification to CAN/CGSB-48.9712 through Natural Resources Canada instead.