Cooling towers steaming at sunrise

Research notes

The technician is the biggest variable in NDT. The report is where it shows.

A 2019 paper on human reliability in nuclear plant inspections argues the technician is the largest source of variation in inspection performance, and counts reporting among the steps where errors enter. Our take: an NDT inspection reporting platform built around the technician is a human-factors control, not paperwork.

Key takeaways

  • A 2019 paper on nuclear plant inspections argues the technician is the largest source of variation in performance.
  • It counts recording and reporting as one of six inspection steps where human errors enter.
  • Our take: an NDT inspection reporting platform built around the technician is a human-factors control.

When an inspection misses a defect, the first instinct is to look at the equipment or the procedure. A paper from Brazil's nuclear technology development center argues that the bigger variable is usually the person: in the authors' words, "the largest source of performance variation can be found in the inspectors."

The paper, by V. Vasconcelos, W. A. Soares, R. O. Marques, S. F. Silva Júnior, and A. L. Raso of CDTN, appeared open access in the Brazilian Journal of Radiation Sciences in 2019. Its setting is nuclear power plants, but its method applies to any weld inspection.

The paper: Human reliability in non-destructive inspections of nuclear power plant components: modeling and analysis, V. Vasconcelos, W. A. Soares, R. O. Marques, S. F. Silva Júnior, A. L. Raso. Brazilian Journal of Radiation Sciences, vol. 7, no. 2B, 2019. DOI 10.15392/bjrs.v7i2B.368.

What the paper covers

The authors review where variation in inspection performance comes from, how human performance in nondestructive inspection has been modeled, and which human reliability analysis techniques suit it. They pick two: failure modes and effects analysis (FMEA), to find and rank likely errors, and the technique for human error rate prediction (THERP), to put numbers on them.

They split a typical inspection into six human steps: defining the inspection strategy, selecting the technique, preparing equipment and procedures, acquiring data, analyzing data, and recording data and reporting. Their worked example is a hypothetical in-service inspection of welds on pipe segments in a plant's core cooling system, by manual ultrasonic testing.

What it found

Inspection performance, the paper argues, depends on the technician's skills, knowledge, and attitude, on the organization they work in, and on physical conditions. In nuclear plants those conditions are hard: radiation, noise, heat, poor lighting, cramped access, and protective equipment, often over long periods on large components. Time pressure and stress raise mental workload and lower performance.

The FMEA names a failure mode for each step. Inspecting the wrong place because of the wrong procedure leads to missed defects. A wrong setup or calibration leads to false calls. Misreading the data leads to wrong recommendations. And at the last step come errors in reporting the inspection, which the authors trace to missing feedback or too little experience.

The THERP example puts numbers on it. With every subtask at its nominal error rate, the estimated reliability of the inspection is high, which the authors call very optimistic. Apply multipliers for working conditions to three of the subtasks and the estimate drops from about 0.97 to about 0.70, closer to the results observed in comparable conditions.

Their recommended actions are practical: risk-based inspection to focus effort; designing the task to fit people's cognitive, physical, and time limits, through training, scheduling, a second technician, access, and usability; more automation where manual inspection hits human limits; and cross-checking results with a complementary technique.

What it means for the report

Reporting is one of the six steps, and every other step ends up in it. A call made right on the scan and recorded wrong on the form is still a wrong report. And reporting often happens at the end of a long shift, away from the component, from notes taken in hard conditions.

Two of the paper's controls apply straight to reporting. Usability: a form that asks for what the procedure needs, in the order the work happens, is a human-factors control. And a second check: the paper lists a second person reviewing the work as human redundancy, and a review only works when the reviewer can see every value and who entered it.

Its limits

The worked example is hypothetical, and its error rates come from general human reliability tables, not from measured inspection data. The authors say so themselves and present the numbers as an illustration of the method.

The setting is also harsher than most weld inspections: radiation, protective equipment, and restricted access. The steps and failure modes carry over; the size of each effect will differ.

Our take

We read this paper as an argument for designing reporting around the technician, not the office. The required fields and the right code should be in front of the technician at the job, while the weld still is, and the report should be built during the inspection, not re-keyed from notes afterwards.

That's what Weld Done is built to do. The job starts from the company's inspection plan, so its procedures come with it. Each RT, VT, and UT indication is checked against the acceptance limits as it's entered. And the report goes to the second signer with its revision history, so that check has something solid to check.

None of this replaces training and experience, which the paper puts at the center. It takes away some of the chances to get the last step wrong.

See how it works on the Standards logic page, or read why NDT service companies switch from Excel and PDF. The NDT reporting checklist has eight ways to get reports right the first time.

ShareLinkedInEmail

Author

Who wrote it.

Nolan Hanson

Nolan Hanson

Product Owner

FAQ

Questions.

Every other answer is on the FAQ page.

Visit FAQ
What is human reliability in NDT?

It's the probability that technicians carry out each inspection task with satisfactory performance. Human reliability analysis predicts where human errors are likely, using techniques such as FMEA and THERP, so they can be designed out or caught.

What are the steps of a nondestructive inspection?

A 2019 paper by Vasconcelos and co-authors lists six: defining the inspection strategy, selecting the technique, preparing equipment and procedures, acquiring data, analyzing data, and recording data and reporting. Each is a point where a human error can enter.

How can human error in NDT be reduced?

The paper recommends risk-based inspection; designing tasks to fit people's limits through training, scheduling, a second technician, access, and usability; more automation where manual work hits human limits; and cross-checking with a complementary technique.

See your own report rebuilt.

Book a 30-minute demo on one of your real reports.

Not ready to talk? The calculator works out hours and costs back from your own numbers.