Visual testing (VT)
The inspector examines the weld directly or with a borescope or camera, and measures size and profile with gauges.
- Procedure
- ASME Section V, Article 9
Markets
Resources
How each method works, where its procedure and acceptance come from, and who's qualified to perform it. A reference for how the industry works, not a list of what Weld Done supports.
The methods
Nondestructive testing (NDT) checks a weld without damaging it. Six methods cover most weld inspection. Three work at the surface, and three look inside the weld.
For every method, acceptance comes from the code the job is built to. Where a pipeline or Canadian code sets its own, the card says so.
At the surface VT · PT · MT
The inspector examines the weld directly or with a borescope or camera, and measures size and profile with gauges.
A liquid penetrant seeps into flaws open to the surface, and a developer draws it back out where it can be seen.
The steel is magnetized, and fine iron particles gather where a flaw disturbs the field.
Inside the weld RT · UT · PAUT
Radiation passes through the weld onto film or a digital detector.
An angle-beam probe sends shear waves into the weld and reads the echoes to locate and size what it finds.
A UT technique that steers the beam electronically and saves the scan as data. It's used in place of RT on many jobs.
Choosing a method
The first question is where the flaw would be. Surface methods (VT, PT, MT) find what breaks or sits just under the surface. Volumetric methods (RT, UT, PAUT) find what's inside the weld. Material narrows it further. MT only works on ferromagnetic steel, so stainless steel and aluminum get PT instead.
In practice the choice is rarely the inspector's. The code the job is built to and the client's specification say which methods apply, how much of each weld is examined, and what passes.
| Method | Where it looks | Works on | Record it leaves |
|---|---|---|---|
| VT | The surface | Any weld | The report, with the measurements |
| PT | Flaws open to the surface | Non-porous metals, including stainless steel and aluminum | The report |
| MT | The surface and just below | Ferromagnetic steel only | The report |
| RT | Inside the weld | Pipeline welds to API 1104, and others to the code the job is built to | A film or digital image |
| UT | Inside the weld | Most metals. Coarse-grained or thin material can be hard to read | The report |
| PAUT | Inside the weld | As for UT | An encoded scan that can be reopened |
Where reports go wrong
Or for limits taken from the wrong code. Weld Done's view: check the code at capture, not after the report is written.
Certification works the same way for all six methods. In the US, NDT inspectors are certified to ASNT's SNT-TC-1A or ANSI/ASNT CP-189. Both are employer-based: the employer certifies its own people against a written practice or the standard, based on training, experience, and exams. SNT-TC-1A is a recommended practice the employer adapts; CP-189 is a standard with fixed minimums. Outside North America, ISO 9712 is the common scheme.
Certification is by method and by level. A Level I performs set tests and records the results under instruction. A Level II sets up and calibrates the equipment, evaluates results against the code, and reports them. A Level III writes and approves procedures, interprets codes, and trains and examines the others. A Level II in UT can't sign an MT report.
The code and the client's specification can add to this, such as radiation safety training for RT, extra training for PAUT, or a Certified Welding Inspector for visual inspection on structural work.

Book a 30-minute demo on one of your real reports.
Not ready to talk? The calculator works out hours and costs back from your own numbers.