NDT methods.

How each method works, where its procedure and acceptance come from, and who's qualified to perform it. A reference for how the industry works, not a list of what Weld Done supports.

The methods

The six NDT methods used on welds.

Nondestructive testing (NDT) checks a weld without damaging it. Six methods cover most weld inspection. Three work at the surface, and three look inside the weld.

For every method, acceptance comes from the code the job is built to. Where a pipeline or Canadian code sets its own, the card says so.

At the surface VT · PT · MT

Inside the weld RT · UT · PAUT

All 57 codes in the Library →

Choosing a method

How the method is chosen.

The first question is where the flaw would be. Surface methods (VT, PT, MT) find what breaks or sits just under the surface. Volumetric methods (RT, UT, PAUT) find what's inside the weld. Material narrows it further. MT only works on ferromagnetic steel, so stainless steel and aluminum get PT instead.

In practice the choice is rarely the inspector's. The code the job is built to and the client's specification say which methods apply, how much of each weld is examined, and what passes.

At a glance.

Each method at a glance: where it looks, what it works on, and the record it leaves
MethodWhere it looksWorks onRecord it leaves
VTThe surfaceAny weldThe report, with the measurements
PTFlaws open to the surfaceNon-porous metals, including stainless steel and aluminumThe report
MTThe surface and just belowFerromagnetic steel onlyThe report
RTInside the weldPipeline welds to API 1104, and others to the code the job is built toA film or digital image
UTInside the weldMost metals. Coarse-grained or thin material can be hard to readThe report
PAUTInside the weldAs for UTAn encoded scan that can be reopened

Where reports go wrong

Most reports come back for one missing field.

Or for limits taken from the wrong code. Weld Done's view: check the code at capture, not after the report is written.

How Standards logic works →

Who's qualified to inspect.

Certification works the same way for all six methods. In the US, NDT inspectors are certified to ASNT's SNT-TC-1A or ANSI/ASNT CP-189. Both are employer-based: the employer certifies its own people against a written practice or the standard, based on training, experience, and exams. SNT-TC-1A is a recommended practice the employer adapts; CP-189 is a standard with fixed minimums. Outside North America, ISO 9712 is the common scheme.

Certification is by method and by level. A Level I performs set tests and records the results under instruction. A Level II sets up and calibrates the equipment, evaluates results against the code, and reports them. A Level III writes and approves procedures, interprets codes, and trains and examines the others. A Level II in UT can't sign an MT report.

The code and the client's specification can add to this, such as radiation safety training for RT, extra training for PAUT, or a Certified Welding Inspector for visual inspection on structural work.

See your own report rebuilt.

Book a 30-minute demo on one of your real reports.

Not ready to talk? The calculator works out hours and costs back from your own numbers.