Code

ANSI/ASNT CP-189: the stricter US standard for NDT certification.

An employer-based certification scheme like SNT-TC-1A, but written as a standard with mandatory requirements instead of guidelines.

Standard for Qualification and Certification of Nondestructive Testing Personnel · ASNT

What it covers

ANSI/ASNT CP-189 in plain terms.

CP-189 covers the same ground as SNT-TC-1A: training, experience, examination, and certification of NDT personnel at three levels, by the employer. The difference is in the word "shall".

Where SNT-TC-1A recommends, CP-189 requires. Minimum training and experience are mandatory, the content of the examinations is set, and the employer's written procedure can't relax them.

The Level III who runs the program must hold ASNT's own NDT Level III certificate, so there's an outside check on the person at the top.

Customers who need more confidence than a recommended practice gives, such as some nuclear and government work, call for CP-189 by name.

In the glossary: Employer-based and central certification · Written practice

Full title
Standard for Qualification and Certification of Nondestructive Testing Personnel
Issued by
American Society for Nondestructive Testing (ASNT), approved as an American National Standard
Type
Standard: its requirements are mandatory, not recommended
Who certifies
The employer, under a written procedure that meets CP-189
Levels
Level I, Level II, Level III
Level III
Must hold a current ASNT NDT Level III certificate
Called for by
ASME codes as an alternative to SNT-TC-1A, and contracts and nuclear work that require it
Related schemes
SNT-TC-1A, the recommended practice · ISO 9712 and CAN/CGSB-48.9712, central certification

Who it's for

One record. Both sides of the job.

How inspection works

Methods under ANSI/ASNT CP-189.

Who sets the procedure, who sets acceptance, and who may do the work, method by method.

MethodProcedureAcceptanceCertification
Every NDT methodThe employer's CP-189 written procedureNot an acceptance standardLevel I, II, or III per method

Acceptance criteria

How a weld passes or fails.

CP-189 doesn't judge welds. It decides who may judge them, with requirements an employer can't soften.

  • Training hours and experience are minimums, not suggestions.
  • Examinations cover general, specific, and practical content, with set passing requirements.
  • Vision is tested every year.
  • The program's Level III holds a current ASNT NDT Level III certificate.
  • Certifications expire and are renewed under the written procedure.

A report signed under CP-189 has to let the reviewer check that the signer was certified, at the right level, in that method, under a compliant procedure.

A summary, not the code. Limits and exceptions are in the edition your job works to.

The report

What a report has to show about who did the work.

The fields a Level III checks before signing. Miss one and the report comes back.

  • Technician name and signature
  • Method and certification level for the method used
  • Certification reference and expiry
  • The employer and written procedure it falls under
  • Reviewer name, level, and sign-off

How Weld Done builds your NDT report template

  1. SNT-TC-1A when the contract says CP-189.

    A technician certified under a recommended-practice program may not meet the contract's mandatory requirements.

  2. Level III without the ASNT certificate.

    Under CP-189 the program's Level III needs ASNT's own certificate. An employer-issued Level III isn't enough.

  3. Expired certification or vision test.

    Lapses happen between jobs. The report is the place they get caught, or missed.

Related codes

The codes around it.

From the blog: Human reliability in NDT

All codes and standards

FAQ

Questions.

Every other answer is on the FAQ page.

Visit FAQ
What's the difference between CP-189 and SNT-TC-1A?

Both are employer-based. SNT-TC-1A is a recommended practice employers adapt; CP-189 is a standard whose requirements are mandatory, including an ASNT Level III certificate for the program's Level III.

Who requires CP-189?

Customers and codes that want mandatory minimums, such as some nuclear and government work. ASME codes accept it as an alternative to SNT-TC-1A.

Who certifies under CP-189?

The employer, under a written procedure that meets the standard. ASNT publishes the standard and certifies Level IIIs, but doesn't certify the employer's Level I and II staff.

Does CP-189 certification transfer between employers?

No. Like SNT-TC-1A, certification is by the employer, so a new employer certifies the technician again.

See your own report rebuilt.

Book a 30-minute demo on one of your real reports.

Not ready to talk? The calculator works out hours and costs back from your own numbers.