Code
EN 1369: magnetic particle testing of castings.
The European standard for magnetic particle testing of ferromagnetic castings, which grades surface indications into severity levels agreed between the foundry and the purchaser.
What it covers
EN 1369 in plain terms.
EN 1369 is the magnetic particle standard written for castings. It sets how a ferromagnetic casting is magnetized and examined, and it grades what is found into severity levels that the foundry and the purchaser agree before the casting is poured.
A casting is not a weld. Its surface indications come from the mould and the solidification: shrinkage, sand and slag at the surface, hot tears, and cold shuts. They can be scattered across a large area rather than lined up along a joint, so the standard judges indications over a reference area placed on the worst part of the casting, not along a length of weld.
Indications are sorted into three kinds: non-linear, linear, and aligned, where several indications in a row act as one. Each kind has its own run of severity levels, from the strictest up, and the levels set the size and number of indications the reference area may hold. The purchaser names a level for each kind, and may name different levels for different zones of the casting.
It covers the test and the grading, not the casting's fitness for purpose. The purchaser decides which levels the part needs, and the order or the drawing records them. Penetrant testing of castings has its own standards, EN 1371-1 and EN 1371-2, and a weld repair on a casting is judged to the weld standards or to the order's repair rules.
Regulation
European steel casting material standards for pressure purposes call up EN 1369 for magnetic particle testing; the order names the severity levels.
- Full title
- Founding — Magnetic particle testing
- Issued by
- CEN, published nationally as BS EN, DIN EN, and NF EN 1369
- Current edition
- EN 1369:2012
- Applies to
- Ferromagnetic iron and steel castings
- Indications
- Non-linear, linear, and aligned, each with its own severity levels
- Judged over
- A reference area placed on the worst part of the casting
- Penetrant companion
- EN 1371-1 and EN 1371-2
- Weld counterparts
- ISO 17638 and ISO 23278
Who it's for
One record. Both sides of the job.
How inspection works
Methods under EN 1369.
Who sets the procedure, who sets acceptance, and who may do the work, method by method.
| Method | Procedure | Acceptance | Certification |
|---|---|---|---|
| Magnetic particle (MT) | EN 1369 | EN 1369 at the severity levels the order names | ISO 9712 MT Level II |
Acceptance criteria
How a weld passes or fails.
Indications in the reference area are sorted by kind, sized or counted, and compared with the severity level the order names for that kind and that zone.
- The purchaser names the severity levels; the standard does not pick them. Without an order there is no acceptance criterion.
- Non-linear indications are judged by size and by how many the area holds.
- Linear and aligned indications are judged by length, and more strictly, because they are the shape of hot tears and cracks.
- The reference area is placed where the indications are worst, so the technician has to search before measuring.
- Zones of one casting can carry different levels, and the report says which zone was judged to which.
- Indications below the recording threshold for the level are not recorded.
Grinding out an indication and retesting is common foundry practice; the report should show what was removed and what the retest found.
A summary, not the code. Limits and exceptions are in the edition your job works to.
The report
What EN 1369 reports have to carry.
The fields a Level III checks before signing. Miss one and the report comes back.
- Casting ID, pattern or drawing number, material grade, and heat number
- Severity levels named in the order, per kind of indication and per zone
- Surface condition and stage of manufacture at test
- Magnetization technique and field verification
- Each recorded indication: kind, location, and size or count within the reference area
- Accept or reject per zone and per casting
- Removal of indications, repair, and retest
- Technician name, ISO 9712 certification, and date
Where reports go wrong
The EN 1369 mistakes that send a report back.
How the job's procedures come from your plan
The NDT reporting checklist: eight ways to get reports right the first time
No severity levels on the order.
EN 1369 grades; it does not choose. A casting tested without named levels has been examined but not accepted.
Reference area placed on a clean patch.
The area goes where the indications are worst. Anywhere else, the grade is flattering and wrong.
Weld limits applied to a casting.
ISO 23278 judges weld indications along a joint. Casting indications are judged by kind over an area, and the levels do not translate.
Related codes
The codes around it.
Edition referenced: EN 1369:2012. All codes and standards
FAQ
Questions.
Every other answer is on the FAQ page.
What is EN 1369?
The European standard for magnetic particle testing of ferromagnetic castings. It sets the technique and grades indications into severity levels by kind: non-linear, linear, and aligned.
Who chooses the EN 1369 severity level?
The purchaser, in the order or on the drawing, usually by zone of the casting. The standard provides the scale, not the choice.
How does EN 1369 differ from ISO 23278?
ISO 23278 judges magnetic particle indications on welds, along a joint. EN 1369 judges indications on castings over a reference area, by kind, at levels the purchaser sets.
What standard covers penetrant testing of castings?
EN 1371-1 for sand, gravity die, and low pressure die castings, and EN 1371-2 for investment castings.

See your own report rebuilt.
Book a 30-minute demo on one of your real reports.
Not ready to talk? The calculator works out hours and costs back from your own numbers.