ISO 17638: magnetic particle testing of welds.
The international standard for finding surface and near-surface cracks in ferromagnetic welds with magnetic particles. Acceptance comes from ISO 23278.
What it covers
ISO 17638 in plain terms.
ISO 17638 sets how to magnetize a weld, apply the particles, and look at the result so that surface-breaking and near-surface flaws show up as indications.
Flaws show best when they lie across the magnetic field, so each area is tested in two directions at roughly right angles. The standard sets the overlap and the field strength needed.
It covers both detection media: fluorescent particles viewed under UV-A light in a darkened area, and colored particles viewed in white light over a contrast background.
It only works on ferromagnetic material. Austenitic stainless steel and aluminum welds need penetrant testing instead.
- Full title
- Non-destructive testing of welds — Magnetic particle testing
- Issued by
- ISO, adopted in Europe as EN ISO 17638
- Current edition
- ISO 17638:2016
- Applies to
- Welds in ferromagnetic materials, including the heat-affected zone
- Techniques
- Yoke, prods, current flow, and coil or cable magnetization
- Detection media
- Fluorescent, or color contrast on a white background
- Acceptance comes from
- ISO 23278
- Personnel
- Certified to ISO 9712 for magnetic particle testing
Who it's for
One record. Both sides of the job.
How inspection works
Methods under ISO 17638.
Who sets the procedure, who sets acceptance, and who may do the work, method by method.
| Method | Procedure | Acceptance | Certification |
|---|---|---|---|
| Magnetic particle (MT), yoke | ISO 17638, two directions per area | ISO 23278 at the acceptance level named | ISO 9712 MT Level II |
| Magnetic particle (MT), prods or current flow | ISO 17638 | ISO 23278 | ISO 9712 MT Level II |
| Magnetic particle (MT), coil or cable | ISO 17638 | ISO 23278 | ISO 9712 MT Level II |
Acceptance criteria
How a weld passes or fails.
ISO 17638 makes the test valid. ISO 23278 then decides which indications are acceptable.
- The tangential field strength at the surface has to be within the range the standard sets, checked with a meter or a flux indicator.
- Each area is tested twice, with the field turned roughly ninety degrees between the two.
- Fluorescent testing needs a minimum UV-A intensity at the surface and low ambient light; color contrast testing needs a minimum white light level.
- Indications are recorded, then judged to ISO 23278 at the acceptance level the specification names.
A summary, not the code. Limits and exceptions are in the edition your job works to.
The report
What ISO 17638 reports have to carry.
The fields a Level III checks before signing. Miss one and the report comes back.
- Weld and component ID, material, and surface condition
- Technique: yoke, prods, current flow or coil, and current type
- Field strength check and how it was verified
- Detection media: fluorescent or color contrast, and the viewing conditions
- Acceptance level applied (ISO 23278)
- Each indication: type, location, and length, and the call
- Demagnetization where required
- Operator name, ISO 9712 certification and date
Where reports go wrong
The ISO 17638 mistakes that send a report back.
How the job's procedures come from your plan
The NDT reporting checklist: eight ways to get reports right the first time
One direction only.
A crack that lies along the field doesn't show. Testing in one direction can pass a cracked weld.
No field check on record.
Without a verified field strength, a clean result proves nothing.
MT on stainless.
Austenitic stainless and aluminum aren't ferromagnetic. Those welds need penetrant testing.
FAQ
Questions.
Every other answer is on the FAQ page.
What does ISO 17638 cover?
Magnetic particle testing of welds in ferromagnetic materials: magnetization techniques, detection media, viewing conditions and recording.
Does ISO 17638 have acceptance criteria?
No. Indications are judged to ISO 23278, at the acceptance level the specification names.
Why test in two directions?
Magnetic particle testing finds flaws that lie across the magnetic field. Testing twice, with the field turned between, catches flaws in any orientation.

See your own report rebuilt.