A gloved hand placing a red magnetic yoke on a steel surface

Method

Magnetic particle testing for weld inspection.

MT magnetizes the steel and dusts it with fine iron particles, which gather wherever a crack breaks the magnetic field. Here's how it's done, which codes set its rules, who can perform it, and what an MT report has to carry.

MT
Where it works
Magnetic metal, such as carbon steel
Procedure
ASME Section V, Article 7; ASTM E709
Acceptance
The code the job is built to
Inspector
Certified to SNT-TC-1A or CP-189

Codes

How it works

Magnetic particle testing in plain terms.

The weld is magnetized with a yoke, prods, or a coil, and fine iron particles are applied, dry or in a liquid. A crack at or just below the surface disturbs the magnetic field, and the particles gather over it into a line the inspector can see, in white light or under UV-A.

It works only on magnetic metal, and it finds a flaw best when the flaw runs across the field, so the inspector tests each area in two directions. On stainless steel or aluminum, penetrant testing is used instead.

In the glossary: Linear and rounded indications · UV-A light · Yoke and prods

Techniques

Magnetizing techniques.

A yoke is the most common choice on welds in the field. It's a portable electromagnet placed across the weld, and it doesn't touch the part with current, so there's no risk of arc strikes. Before use, the yoke has to pass a lifting power check: under ASME Section V, Article 7, an AC yoke lifts at least 10 lb (4.5 kg) and a DC yoke at least 40 lb (18 kg) at its maximum pole spacing.

Prods pass current through the part between two contact points. They magnetize larger areas but can leave arc strikes, so some specifications restrict them. A coil or cable wrap around a pipe or shaft sets up a field along its length.

AC current concentrates the field at the surface and is the best choice for surface cracks. DC and half-wave DC reach further below the surface.

Particles and field checks.

Dry powder suits rough surfaces and hot parts. Wet particles, suspended in a carrier, are more sensitive on smooth surfaces, and wet fluorescent particles under UV-A are the most sensitive of all.

The field has to be strong enough and in the right direction, and the procedure says how that's shown: a pie gauge, artificial flaw shims, or a gaussmeter. Each area is tested twice, with the second field at roughly 90 degrees to the first, so a crack running in any direction is caught.

Where the remaining magnetism would affect later welding, machining, or service, the part is demagnetized.

Strengths and limits

Where MT works and where it stops.

It's fast and portable, and it finds fine cracks, including some just below the surface that penetrant would miss. It needs less surface preparation than penetrant testing.

It works only on ferromagnetic material, so not on stainless steel or aluminum. It finds flaws best when they lie across the magnetic field. That's why each area is magnetized in two directions and why the report records both.

Who can perform MT

Who can perform MT.

MT inspectors are certified to SNT-TC-1A or CP-189, like inspectors for every other method, usually at Level II to evaluate indications and sign the report. Certification is method-specific, so an inspector certified in PT isn't certified in MT, even though both are surface methods on the same weld.

The report

What an MT report has to carry.

The fields a Level III checks before signing, in the order the report runs. Miss one and the report comes back.

The job

  • Job, client, and location
  • Drawing or line number
  • Weld ID and welder ID

Procedure and material

  • WPS reference
  • Material, diameter, and wall thickness
  • Governing code and the acceptance criteria applied

Technique and equipment

  • Technique: yoke, prods, or coil, and the current used
  • Particles: wet or dry, visible or fluorescent
  • Field check, such as a field indicator
  • Directions tested
  • Surface preparation
  • Lighting: white light, or UV-A for fluorescent
  • Demagnetization, where required

Results

  • Each indication: type, location, size, and the accept or reject call
  • Final disposition per weld
  • Repair tracking

Sign-off

  • Technician name, cert level, and signature
  • Reviewer sign-off and date

How Weld Done builds your NDT report template

Where reports go wrong

What sends an MT report back.

Only one direction tested
A crack running the same way as the field barely shows. A report with one direction on it can miss exactly that crack.
Field not checked
No field indicator or strength check on the record, so nothing shows the weld was magnetized enough to find anything.
Wrong lighting for the particles
Fluorescent particles read under white light, or with no UV-A reading on the report.

The NDT reporting checklist: eight ways to get reports right the first time

FAQ

Questions.

Every other answer is on the FAQ page.

Visit FAQ
What does a magnetic particle inspection report have to include?

The job and weld, the procedure and material, the governing code and acceptance criteria, the technique and current, the particles used, the field check and the directions tested, the lighting, each indication with its call, and the technician's and reviewer's signatures.

Can MT be used on stainless steel?

Not on austenitic stainless steel, which isn't magnetic. Penetrant testing is used on it instead.

AC or DC yoke: which is better?

For surface cracks on welds, AC is usually preferred because it concentrates the field at the surface. DC reaches a little further below the surface. The procedure for the job says which is used, and the report records it.

Why is each area tested in two directions?

MT finds a flaw best when it lies across the magnetic field. A crack running along the field barely shows, so a second test at about 90 degrees catches what the first one missed.

Can we download a MT report template?

Not yet. Until there's a sample report we can publish, this page lists everything the report has to carry.

A summary, not the code: procedures and limits are in the edition your job works to.

See your own report rebuilt.

Book a 30-minute demo on one of your real reports.

Not ready to talk? The calculator works out hours and costs back from your own numbers.