Code

ISO 23278: acceptance levels for magnetic particle testing.

The international standard that decides whether a magnetic particle indication on a weld is acceptable, at one of three acceptance levels.

Non-destructive testing of welds — Magnetic particle testing — Acceptance levels · ISO · ISO 23278:2015

What it covers

ISO 23278 in plain terms.

ISO 23278 is the acceptance half of magnetic particle testing on welds. ISO 17638 produces the indications; ISO 23278 decides which ones the weld can keep.

It sorts indications into linear and non-linear by their shape: an indication much longer than it is wide is linear, and linear indications are treated more strictly because they usually mean cracks or lack of fusion.

It works in three acceptance levels matched to ISO 5817 quality levels. The design names the quality level, and the acceptance level follows.

Indications below a recording level aren't recorded at all. Above it, each is measured and judged against the limit for its type and level.

Full title
Non-destructive testing of welds — Magnetic particle testing — Acceptance levels
Issued by
ISO, adopted in Europe as EN ISO 23278
Current edition
ISO 23278:2015
Acceptance levels
1, 2, and 3, from the strictest
Linked to
ISO 5817 quality levels B, C, and D
Technique standard
ISO 17638
Indications
Linear and non-linear, judged by length

Who it's for

One record. Both sides of the job.

How inspection works

Methods under ISO 23278.

Who sets the procedure, who sets acceptance, and who may do the work, method by method.

MethodProcedureAcceptanceCertification
Magnetic particle (MT)ISO 17638ISO 23278 at acceptance level 1, 2, or 3ISO 9712 MT Level II

Acceptance criteria

How a weld passes or fails.

Each indication is classed as linear or non-linear, measured, and judged against the length limit for the acceptance level.

  • Indications below the recording level are ignored.
  • Linear indications have tighter length limits than non-linear ones at every acceptance level.
  • Acceptance level 1 is the strictest; acceptance level 3 allows the longest indications.
  • Grouped indications can be judged together where they're close enough to act as one.
  • A weld with an unacceptable indication is repaired, or the indication is investigated further, then the weld is retested.

The report has to state the acceptance level, because the same indication can pass at acceptance level 3 and fail at acceptance level 1.

A summary, not the code. Limits and exceptions are in the edition your job works to.

The report

What ISO 23278 reports have to carry.

The fields a Level III checks before signing. Miss one and the report comes back.

  • Weld and component ID
  • ISO 5817 quality level and ISO 23278 acceptance level applied
  • Reference to the ISO 17638 test record
  • Each recorded indication: linear or non-linear, location, and length
  • Accept or reject per indication and per weld
  • Repairs and retest
  • Interpreter name, ISO 9712 certification and date

How Weld Done builds your NDT report template

  1. No acceptance level stated.

    Without it, an MT call can't be checked against what the design asked for.

  2. Linear judged as non-linear.

    A crack-like indication measured against the looser non-linear limit passes when it shouldn't.

  3. Indications not measured.

    Acceptance is by length. An indication described but not measured can't be judged.

Related codes

The codes around it.

Edition referenced: ISO 23278:2015. All codes and standards

FAQ

Questions.

Every other answer is on the FAQ page.

Visit FAQ
What are ISO 23278 acceptance levels?

Three levels, 1 to 3, with level 1 the strictest. They match ISO 5817 quality levels B, C, and D.

What's a linear indication?

An indication much longer than it is wide. Linear indications usually mean cracks or lack of fusion, so they have tighter limits than rounded, non-linear ones.

How does ISO 23278 relate to ISO 17638?

ISO 17638 sets how the magnetic particle test is done. ISO 23278 sets which of the resulting indications are acceptable.

See your own report rebuilt.

Book a 30-minute demo on one of your real reports.

Not ready to talk? The calculator works out hours and costs back from your own numbers.