Code

ISO 23277: acceptance levels for penetrant testing.

The international standard that decides whether a penetrant indication on a weld is acceptable, at one of three acceptance levels.

Non-destructive testing of welds — Penetrant testing — Acceptance levels · ISO · ISO 23277:2015

What it covers

ISO 23277 in plain terms.

ISO 23277 is the acceptance half of penetrant testing on welds. ISO 3452-1 produces the indications; ISO 23277 decides which ones the weld can keep. It applies to surface-breaking imperfections in welds in metallic materials.

It sorts indications into linear and non-linear by their shape: an indication much longer than it is wide is linear, and linear indications are treated more strictly because they usually mean cracks or lack of fusion at the surface.

It works in three acceptance levels matched to the quality levels of ISO 5817 for steel and ISO 10042 for aluminum. The design names the quality level, the application standard or ISO 17635 maps it to an acceptance level, and the test is judged there. The standard also recommends testing parameters for each level: surface preparation, penetrant system sensitivity, and viewing conditions.

Indications below a recording level aren't recorded at all. Above it, each is measured and judged against the limit for its type and level. A weld that fails can be repaired and retested, or the indication investigated further, as the application standard allows.

Regulation

In Europe the standard is EN ISO 23277, and EN 1090-2 points to it for penetrant acceptance on structural welds, by execution class.

Full title
Non-destructive testing of welds — Penetrant testing — Acceptance levels
Issued by
ISO, adopted in Europe as EN ISO 23277
Current edition
ISO 23277:2015
Acceptance levels
1, 2, and 3, from the strictest
Linked to
ISO 5817 and ISO 10042 quality levels, through ISO 17635
Technique standard
ISO 3452-1
Indications
Linear and non-linear, judged by length
Twin for MT
ISO 23278

Who it's for

One record. Both sides of the job.

How inspection works

Methods under ISO 23277.

Who sets the procedure, who sets acceptance, and who may do the work, method by method.

MethodProcedureAcceptanceCertification
Penetrant (PT)ISO 3452-1ISO 23277 at acceptance level 1, 2, or 3ISO 9712 PT Level II

Acceptance criteria

How a weld passes or fails.

Each indication is classed as linear or non-linear, measured, and judged against the length limit for the acceptance level.

  • Indications below the recording level are ignored.
  • Linear indications have tighter length limits than non-linear ones at every acceptance level.
  • Acceptance level 1 is the strictest; acceptance level 3 allows the longest indications.
  • The penetrant system and the viewing conditions have to suit the level: a stricter level calls for a more sensitive system and better surface preparation.
  • ISO 17635 can name a level with a suffix that tightens the limit for linear indications; the report states the level exactly as the application standard writes it.
  • A weld with an unacceptable indication is repaired, or the indication is investigated further, then the weld is retested.

The report has to state the acceptance level, because the same indication can pass at acceptance level 3 and fail at acceptance level 1.

A summary, not the code. Limits and exceptions are in the edition your job works to.

The report

What ISO 23277 reports have to carry.

The fields a Level III checks before signing. Miss one and the report comes back.

  • Weld and component ID, material, and surface condition
  • ISO 5817 or ISO 10042 quality level, and the ISO 23277 acceptance level applied
  • Reference to the ISO 3452-1 test record: penetrant system, dwell, and viewing conditions
  • Each recorded indication: linear or non-linear, location, and length
  • Accept or reject per indication and per weld
  • Repairs and retest
  • Interpreter name, ISO 9712 certification, and date

How Weld Done builds your NDT report template

  1. No acceptance level stated.

    Without it, a penetrant call can't be checked against what the design asked for.

  2. Linear judged as non-linear.

    A crack-like indication measured against the looser non-linear limit passes when it shouldn't.

  3. System too coarse for the level.

    A low-sensitivity penetrant on a rough surface can't show what acceptance level 1 expects to be found. The recommended testing parameters exist for that reason.

  4. Indications not measured.

    Acceptance is by length. An indication described but not measured can't be judged.

Related codes

The codes around it.

Edition referenced: ISO 23277:2015. All codes and standards

FAQ

Questions.

Every other answer is on the FAQ page.

Visit FAQ
What are ISO 23277 acceptance levels?

Three levels, 1 to 3, with level 1 the strictest. They are matched to ISO 5817 and ISO 10042 quality levels through ISO 17635 and the application standard.

What's a linear indication in penetrant testing?

An indication much longer than it is wide. On a weld surface it usually means a crack or lack of fusion, so it has tighter limits than a rounded, non-linear one.

How does ISO 23277 relate to ISO 3452-1?

ISO 3452-1 sets how the penetrant test is done. ISO 23277 sets which of the resulting indications on a weld are acceptable.

What's the difference between ISO 23277 and ISO 23278?

Same structure, different method. ISO 23277 is the acceptance standard for penetrant testing of welds; ISO 23278 is the one for magnetic particle testing.

See your own report rebuilt.

Book a 30-minute demo on one of your real reports.

Not ready to talk? The calculator works out hours and costs back from your own numbers.