Method
Penetrant testing for weld inspection.
PT draws a colored or fluorescent liquid into cracks that break the surface, then pulls it back out where the inspector can see it. Here's how it's done, which codes set its rules, who can perform it, and what a PT report has to carry.
- Where it works
- Non-porous metals, including stainless steel and aluminum
- Procedure
- ASME Section V, Article 6; ASTM E165
- Acceptance
- The code the job is built to
- Inspector
- Certified to SNT-TC-1A or CP-189
How it works
Penetrant testing in plain terms.
The surface is cleaned, then a liquid penetrant is applied and left to dwell, so it seeps into any crack open to the surface. The excess is removed, and a developer draws the penetrant back out, so the flaw shows as a red or fluorescent line.
It finds only what breaks the surface, but it works on metals magnetic particle testing can't, such as stainless steel and aluminum. Cleaning and dwell times decide whether it works, which is why they belong on the report.
In the glossary: Linear and rounded indications · UV-A light
Techniques
Penetrant systems and techniques.
Penetrants come in two types. Type I is fluorescent: it's read under UV-A light in a darkened area, and it's the more sensitive of the two. Type II is visible red dye, read in white light. Most field work on welds uses solvent-removable visible dye from aerosol cans, because it needs no water, power, or dark room.
How the excess penetrant comes off defines the method: water-washable, post-emulsifiable, or solvent-removable. Over-cleaning is the common mistake. Wiping the surface with solvent straight from the can can wash the penetrant out of the very cracks the test is looking for, so the solvent goes on a cloth first.
Developers come as dry powder, water-based, or nonaqueous. Nonaqueous developer, sprayed in a thin, even coat, is the usual choice with solvent-removable penetrant.
What the procedure controls.
ASME Section V, Article 6 sets minimum dwell and development times, and the procedure for the job can require longer. The surface and the penetrant have to be within the qualified temperature range, normally 40 to 125°F (5 to 52°C). Outside that range, the procedure has to be qualified for the temperature used.
On nickel alloys, austenitic stainless steel, and titanium, the penetrant materials must be certified low in sulfur or halogens, since those contaminants can attack the metal. For fluorescent penetrant, the procedure sets a minimum UV-A intensity at the surface and a maximum of ambient white light, and the inspector's eyes adapt to the dark before reading.
Strengths and limits
Where PT works and where it stops.
It works on almost any non-porous metal, including stainless steel and aluminum where magnetic particle testing can't be used. It's portable, cheap, and sensitive to fine surface cracks.
It only finds flaws open to the surface, and only on a clean one. Paint, scale, or oil in a crack keeps the penetrant out. Results depend on cleaning, dwell time, and temperature, which is why those belong on the report.
Who can perform PT
Who can perform PT.
PT inspectors are certified to SNT-TC-1A or CP-189, like inspectors for every other method, usually at Level II to evaluate indications and sign the report. Because PT relies on seeing red dye against a white developer, or a fluorescent glow under UV-A, the yearly near-vision exam and the color contrast check matter here as much as anywhere.
The report
What a PT report has to carry.
The fields a Level III checks before signing, in the order the report runs. Miss one and the report comes back.
The job
- Job, client, and location
- Drawing or line number
- Weld ID and welder ID
Procedure and material
- WPS reference
- Material, diameter, and wall thickness
- Governing code and the acceptance criteria applied
Technique and equipment
- Penetrant system: visible or fluorescent, and how the excess is removed
- Penetrant, remover, and developer, with batch numbers
- Surface preparation and cleaning
- Dwell and development times
- Surface temperature
- Lighting: white light, or UV-A for fluorescent
Results
- Each indication: type, location, size, and the accept or reject call
- Final disposition per weld
- Repair tracking
Sign-off
- Technician name, cert level, and signature
- Reviewer sign-off and date
Where reports go wrong
What sends a PT report back.
- Dwell time not recorded
- The penetrant may have had its full dwell, but with no time on the report the Level III can't show it did.
- Materials not traceable
- Penetrant, remover, and developer with no batch numbers, so a bad batch can't be traced to the welds it touched.
- Surface not prepared
- Paint, scale, or spatter left on the weld, hiding the very cracks the test is meant to find.
The NDT reporting checklist: eight ways to get reports right the first time
FAQ
Questions.
Every other answer is on the FAQ page.
What does a penetrant testing report have to include?
The job and weld, the procedure and material, the governing code and acceptance criteria, the penetrant system and its batch numbers, the surface preparation, dwell and development times, the surface temperature and lighting, each indication with its call, and the technician's and reviewer's signatures.
Visible or fluorescent penetrant: does the report change?
The fields stay the same. The report records which system was used, and fluorescent penetrant adds the UV-A lighting check.
How long should the penetrant dwell?
At least as long as the procedure says. ASME Section V, Article 6 sets minimum dwell times, and the procedure for the job can require more. The time actually used goes on the report.
Can PT be used on stainless steel?
Yes. It's the usual surface method on austenitic stainless steel, which isn't magnetic. The penetrant materials must be certified low in halogens.
Can we download a PT report template?
Not yet. Until there's a sample report we can publish, this page lists everything the report has to carry.
A summary, not the code: procedures and limits are in the edition your job works to.

See your own report rebuilt.
Book a 30-minute demo on one of your real reports.
Not ready to talk? The calculator works out hours and costs back from your own numbers.