ASTM E2700: contact ultrasonic testing of welds with phased arrays.

The ASTM practice for phased array ultrasonic testing of welds: how the focal laws and scan plan are set, how the array is calibrated, how the scan is encoded and recorded, and where acceptance comes from.

Contact Ultrasonic Testing of Welds Using Phased Arrays · ASTM International

What it covers

ASTM E2700 in plain terms.

E2700 takes the contact ultrasonic testing of welds in ASTM E164 and sets it out for phased array probes: an array of elements fired with time delays, so one probe position sweeps a range of angles or steps a beam along the array. It covers the equipment, the focal laws, the scan plan, calibration, scanning, and data recording.

The scan plan is the document that makes the technique defensible. For the joint geometry it shows the probe positions, the angles and focal laws, and that the beams cover the full weld volume and heat-affected zone, usually with ray-tracing software. The plan and the setup file are part of the record.

Calibration is done per focal law, not once. Velocity and wedge delay are set on a known block, and sensitivity is set so a reference reflector reads the same at every angle and depth the plan uses, with time-corrected gain. Encoded scanning ties every A-scan to a position along the weld, and the data is saved so the scan can be re-read later without re-scanning the weld.

E2700 doesn't accept or reject welds. ASME Section VIII does for vessels, through the Section V Article 4 appendices that cover phased array, CSA Z662 Clause 7 does for Canadian pipeline girth welds, API 1104 does for pipelines in its ultrasonic clauses, and the purchase specification does elsewhere.

In the glossary: Encoded scan · Scan plan

Full title
Standard Practice for Contact Ultrasonic Testing of Welds Using Phased Arrays
Issued by
ASTM International
Current edition
ASTM E2700, edition to confirm
Applies to
Phased array examination of welds in plate, pipe, and vessels, by hand or with an encoder
Scan plan
A documented plan showing the beams cover the weld volume and heat-affected zone for the joint geometry
Calibration
Velocity, wedge delay, and sensitivity for every focal law, on blocks of similar material
Acceptance comes from
The construction code: ASME Section VIII, CSA Z662 Clause 7, API 1104, or the purchase specification
Personnel
SNT-TC-1A or CP-189 UT Level II, with phased array training and qualification

Who it's for

One record. Both sides of the job.

How inspection works

Methods under ASTM E2700.

Who sets the procedure, who sets acceptance, and who may do the work, method by method.

MethodProcedureAcceptanceCertification
Phased array (PAUT), manualASTM E2700, with a scan plan for the jointThe code the job is built to: ASME Section VIII or the purchase specificationSNT-TC-1A or CP-189 UT Level II with phased array qualification
Phased array (PAUT), encodedASTM E2700, with encoded line scans and stored dataThe code the job is built to: CSA Z662 Clause 7, API 1104, or ASME Section VIIISNT-TC-1A or CP-189 UT Level II with phased array qualification

Acceptance criteria

How a weld passes or fails.

E2700 sets no accept or reject limits. Its controls decide whether the phased array scan is worth reading.

  • A scan plan for the joint geometry shows that the chosen angles and probe positions cover the weld volume and heat-affected zone.
  • Velocity, wedge delay, and sensitivity are calibrated for every focal law in the plan, on blocks acoustically similar to the part, with time-corrected gain where depth varies.
  • The encoder is checked for accuracy, and the scan is repeated where data is missing along the weld or couplant was lost.
  • Scanning covers the sides and faces the plan requires, at the index offset and scan speed the procedure allows.
  • Every indication is located in the data, sized the way the procedure says, and kept with the scan file so a reviewer can see the same image.
  • Calibration is verified at the end of the scan and whenever the setup changes, and work since the last good check is repeated if it drifted.

The stored data is the examination. A report without the data file, the scan plan, and the calibration record can't be checked.

A summary, not the code. Limits and exceptions are in the edition your job works to.

The report

What ASTM E2700 reports have to carry.

The fields a Level III checks before signing. Miss one and the report comes back.

  • Weld ID, joint geometry, material, and thickness
  • Instrument, array probe, and wedge: elements, pitch, frequency, and wedge angle
  • Scan plan reference and the focal laws used: angles, apertures, and focal depths
  • Calibration blocks, reference reflectors, sensitivity settings, and time-corrected gain
  • Encoder type, resolution, and any missing-data allowance applied
  • Scan coverage: probe positions, index offsets, and areas not accessible
  • Each indication: position, depth, length, height where measured, and the call against the named code
  • Data file name, software version, technician name, certification level, and signature

How Weld Done builds your NDT report template

  1. No scan plan on file.

    Without it, nobody can show the beams reached the whole weld. A clean scan of half the volume is not a clean weld.

  2. Sensitivity set at one angle.

    A reference reflector that reads right at one angle can read low at another. Calibration per focal law is what makes the amplitudes comparable.

  3. Missing data accepted.

    Gaps where the encoder slipped or couplant was lost are unexamined weld. The procedure sets how much is tolerated, and the rest has to be rescanned.

  4. E2700 cited as the acceptance standard.

    It sets how the scan is made and recorded. The height and length limits come from the construction code, such as CSA Z662 Clause 7 or ASME Section VIII.

FAQ

Questions.

Every other answer is on the FAQ page.

Visit FAQ
What is ASTM E2700?

The ASTM practice for phased array ultrasonic testing of welds: equipment, focal laws, scan plans, calibration, encoded scanning, and data recording. The construction code sets acceptance.

What is a focal law?

The set of firing delays for the elements of the array that produces one beam at one angle and focal depth. A sectorial scan is a sequence of focal laws across a range of angles.

What is a scan plan?

A documented layout, usually from ray-tracing software, that shows for the joint geometry which probe positions and angles cover the weld volume and heat-affected zone. E2700 expects one for each configuration.

Does ASTM E2700 have acceptance criteria?

No. It makes the scan valid and repeatable. ASME Section VIII, CSA Z662 Clause 7, API 1104, or the purchase specification decides what passes.

Can phased array replace radiography?

Often, where the construction code allows ultrasonic examination in place of radiography and the procedure is qualified for the joint. The code, not E2700, decides when the substitution is allowed.

See your own report rebuilt.

Book a 30-minute demo on one of your real reports.

Not ready to talk? The calculator works out hours and costs back from your own numbers.