ASTM E164: contact ultrasonic testing of weldments.

The ASTM practice for conventional, hand-held ultrasonic testing of welds: how the instrument is calibrated, how the weld is scanned, and what is recorded, with acceptance left to the construction code.

Contact Ultrasonic Testing of Weldments · ASTM International

What it covers

ASTM E164 in plain terms.

E164 is the practice for conventional contact ultrasonic testing of welds: a single-element probe, couplant, and a hand scan. It covers the instrument and probes, the reference blocks, calibration, the scanning pattern for each joint type, and what is recorded about the indications found.

Calibration is built on reference blocks of material acoustically similar to the part. The straight beam is set on a block of known thickness; the angle beam gets its exit point, angle, and sensitivity from an IIW or similar block, and its distance-amplitude correction from side-drilled holes in a basic calibration block of the right thickness. The reference level is set before scanning and checked at the end.

Scanning follows the joint. The base metal is checked with a straight beam first, for laminations that would block the angle beam, then the weld and heat-affected zone are swept from both sides and both faces where access allows, at a scanning gain above the reference level. Annexes cover the common joint configurations in plate and pipe.

E164 records and describes indications; it doesn't accept or reject them. ASME Section VIII, API 1104, and purchase specifications supply the limits. AWS D1.1 writes its own ultrasonic procedure and acceptance into the code, so E164 is a background reference there rather than the governing procedure.

Full title
Standard Practice for Contact Ultrasonic Testing of Weldments
Issued by
ASTM International
Current edition
ASTM E164, edition to confirm
Applies to
Pulse-echo contact testing of welds in ferrous and aluminum alloys, in plate, pipe, and structural shapes
Techniques
Straight beam for the base metal, angle beam through the weld and heat-affected zone
Calibration
IIW and similar reference blocks, and a basic calibration block with side-drilled holes for distance-amplitude correction
Acceptance comes from
The construction code: ASME Section VIII, AWS D1.1, API 1104, or the purchase specification
Personnel
SNT-TC-1A or CP-189 UT Level II

Who it's for

One record. Both sides of the job.

How inspection works

Methods under ASTM E164.

Who sets the procedure, who sets acceptance, and who may do the work, method by method.

MethodProcedureAcceptanceCertification
Ultrasonic (UT), straight beamASTM E164, base metal checkThe code the job is built toSNT-TC-1A or CP-189 UT Level II
Ultrasonic (UT), angle beamASTM E164, weld and heat-affected zoneThe code the job is built to: ASME Section VIII, API 1104, or the purchase specificationSNT-TC-1A or CP-189 UT Level II

Acceptance criteria

How a weld passes or fails.

E164 sets no accept or reject limits. Its controls decide whether the scan found what it should have found.

  • The instrument's linearity is verified on the schedule the procedure sets, and the result is on record.
  • Calibration is done on blocks of acoustically similar material, with the reference level and distance-amplitude correction established before scanning.
  • The base metal is scanned with a straight beam so laminations don't hide weld flaws from the angle beam.
  • The weld is scanned from the sides and faces the procedure requires, with overlap between passes and the scanning gain the procedure names.
  • Each indication above the recording level is located, its amplitude against the reference level is noted, and its length is measured the way the procedure says.
  • Calibration is rechecked at the end of the shift or whenever the setup changes, and work since the last good check is rescanned if it drifted.

With those on record, the construction code's criteria, usually by amplitude and length, decide each indication.

A summary, not the code. Limits and exceptions are in the edition your job works to.

The report

What ASTM E164 reports have to carry.

The fields a Level III checks before signing. Miss one and the report comes back.

  • Weld ID, joint type, material, and thickness
  • Instrument and probe: make, frequency, size, and nominal and measured angle
  • Calibration blocks, reference level, and distance-amplitude correction
  • Couplant and surface condition
  • Scanning: faces and sides covered, scanning gain, and any area not accessible
  • Each indication: location along and across the weld, depth, amplitude against reference, and length
  • The code whose acceptance criteria were applied, and the call for each indication
  • Technician name, certification level, and signature

How Weld Done builds your NDT report template

  1. No base metal scan.

    A lamination under the probe reflects the angle beam before it reaches the weld. Without the straight beam check, missed coverage looks like a clean weld.

  2. Calibration block of the wrong material.

    Velocity and attenuation differ between alloys. A block that doesn't match the part puts the reference level in the wrong place.

  3. Inaccessible areas not reported.

    A nozzle or a backing bar can block part of the scan. If the report doesn't say so, the reader assumes full coverage.

  4. E164 cited as the acceptance standard.

    E164 says how to scan and what to record. The amplitude and length limits come from the construction code.

FAQ

Questions.

Every other answer is on the FAQ page.

Visit FAQ
What is ASTM E164?

The ASTM practice for conventional contact ultrasonic testing of welds: equipment, reference blocks, calibration, scanning, and recording. The construction code sets acceptance.

Does ASTM E164 have acceptance criteria?

No. It describes how to scan and what to record. ASME Section VIII, AWS D1.1, API 1104, or the purchase specification decides which indications are acceptable.

What's the difference between ASTM E164 and ASME Section V Article 4?

Both set how welds are examined ultrasonically. Article 4 is ASME's own article and governs ASME code work. E164 is the ASTM practice cited where a specification or purchase order calls for it.

What's the difference between ASTM E164 and ASTM E2700?

E164 is conventional UT with a single-element probe swept by hand. E2700 is the same job with a phased array probe, steering the beam electronically and recording the scan as data.

What is the ISO equivalent of ASTM E164?

ISO 17640 covers ultrasonic testing of welds internationally, with ISO 11666 for acceptance levels. They're the usual references in Europe.

See your own report rebuilt.

Book a 30-minute demo on one of your real reports.

Not ready to talk? The calculator works out hours and costs back from your own numbers.