Method
Phased array ultrasonic testing for weld inspection.
PAUT steers an ultrasonic beam electronically, sweeping the weld from one position and saving the scan as data. Here's how it's done, which codes set its rules, who can perform it, and what a PAUT report has to carry.
- Used for
- Pipeline and plant welds, often in place of RT
- Procedure
- ASME Section V, Article 4; ASTM E2700
- Acceptance
- The code the job is built to; CSA Z662 Clause 7 in Canada
- Inspector
- Certified in UT to SNT-TC-1A or CP-189, with added PAUT training
How it works
Phased array ultrasonic testing in plain terms.
A probe made of many small elements steers and focuses the sound beam electronically, sweeping a range of angles from one position. An encoder records where the probe is, so the whole scan is saved as data that can be reviewed after the job.
That makes PAUT a common replacement for RT on many jobs: no radiation, an encoded record that can be reopened, and, like conventional UT, a flaw's height as well as its length. The scan plan and the setup file are part of the record, so they belong with the report.
In the glossary: Encoded scan · Scan plan
Techniques
Scan types and the scan plan.
A sectorial scan (S-scan) sweeps the beam through a range of angles, such as 40 to 70 degrees, from one probe position. A linear scan (E-scan) holds one angle and steps the beam along the length of the probe. On welds, the probe usually runs along the weld at a fixed distance from it in an encoded line scan, so one pass records the whole weld.
The scan plan is the drawing that shows where the probe sits, which angles and focal laws are used, and how the beams cover the weld and heat-affected zone. It's prepared before the job, often modeled in software, and it's what a reviewer uses to confirm coverage. PAUT is often paired with TOFD, which adds a second, independent view for sizing.
Calibration uses reference blocks to set the sensitivity across every angle and depth, through time-corrected gain (TCG) or angle-corrected gain (ACG), and to check the encoder's distance against a known length.
Where PAUT replaces RT.
Codes such as ASME Section VIII and ASME B31.3 allow ultrasonic testing, including PAUT, in place of radiography under set conditions, and CSA Z662 Clause 7 sets acceptance for it on Canadian pipelines. The appeal is practical: no radiation exclusion zone, so other trades keep working, and results on site instead of after film processing. Whether it's allowed on a given job is up to the code and the client's specification.
Strengths and limits
Where PAUT works and where it stops.
It sweeps many angles from one position, so it covers the weld quickly, and it saves an encoded, imaged scan that can be reopened after the job. Like conventional UT, it sizes what it finds. With no radiation, it replaces RT on many pipeline and plant jobs.
Setup is more complex than conventional UT, inspectors need PAUT training on top of their UT certification, and the result is only as good as the scan plan. If the plan and the data files aren't tied to the report, the stored record can't prove the weld was covered.
Who can perform PAUT
Who can perform PAUT.
PAUT is a technique of ultrasonic testing, not a separate method. Inspectors are certified in UT to SNT-TC-1A or CP-189, like inspectors for every other method, with additional PAUT training and hands-on experience set by the employer's written practice. Many codes and clients also require a practical demonstration on samples with known flaws before an inspector works on their welds.
The report
What a PAUT report has to carry.
The fields a Level III checks before signing, in the order the report runs. Miss one and the report comes back.
The job
- Job, client, and location
- Drawing or line number
- Weld ID and welder ID
Procedure and material
- WPS reference
- Material, diameter, and wall thickness
- Governing code and the acceptance criteria applied
Technique and equipment
- Instrument, probe, and wedge
- Focal laws and the scan plan
- Encoder and scan positions
- Calibration and the reference blocks used
- Data file names, kept with the report
Results
- Each indication: location, height, length, and the accept or reject call
- Final disposition per weld
- Repair tracking
Sign-off
- Technician name, cert level, and signature
- Reviewer sign-off and date
Where reports go wrong
What sends a PAUT report back.
- Scan plan not attached
- The report gives results but not the plan they came from, so a reviewer can't confirm the beams covered the whole weld.
- Data not linked to the report
- The scan file saved under a name nobody can match to the weld, so the stored record can't be reopened when it's needed.
- Encoder not checked
- Positions read from an encoder nobody checked, so a flaw's location on the weld can be off.
The NDT reporting checklist: eight ways to get reports right the first time
FAQ
Questions.
Every other answer is on the FAQ page.
What does a phased array report have to include?
The job and weld, the procedure and material, the governing code and acceptance criteria, the instrument, probe, and wedge, the focal laws and scan plan, the encoder and calibration, the data file names, each indication with its location, height, length, and call, and the technician's and reviewer's signatures.
Is PAUT accepted in place of RT?
On many jobs, where the code and the client's specification allow it. In Canada, CSA Z662 Clause 7 sets PAUT acceptance for pipelines.
Does PAUT need a separate certification?
No separate method certification. PAUT is certified as a technique of UT under SNT-TC-1A or CP-189, with added PAUT training and experience. Some codes and clients also require a practical demonstration.
What does PAUT add over conventional UT?
Coverage and a record. Both locate and size flaws. PAUT sweeps many angles from one position and saves an encoded scan that a reviewer can reopen, while conventional UT is moved by hand and the report is the only record.
Can we download a PAUT report template?
Not yet. Until there's a sample report we can publish, this page lists everything the report has to carry.
A summary, not the code: procedures and limits are in the edition your job works to.

See your own report rebuilt.
Book a 30-minute demo on one of your real reports.
Not ready to talk? The calculator works out hours and costs back from your own numbers.