Code
ASTM E709: a guide to magnetic particle testing.
The ASTM guide that describes the techniques, materials, and checks of magnetic particle testing for general industry. It is written as a guide, so the written procedure and the referencing code decide what applies, and acceptance comes from the code the job is built to.
What it covers
ASTM E709 in plain terms.
E709 describes magnetic particle testing from end to end: how to magnetize a ferromagnetic part, which particles to apply, how to tell the field is strong enough and pointing the right way, and how to demagnetize afterward. It is a guide, not a practice, so it lays out the options and the written procedure or the referencing code picks among them.
Magnetization comes from yokes, prods, coils, cable wraps, a central conductor, or current passed directly through the part. Alternating current favors surface flaws; rectified current reaches a little deeper. Flaws show best when they cross the field, so each area is tested in two directions at roughly right angles.
Particles are dry powder or a wet suspension in oil or water, in visible colors for white light or fluorescent for UV-A. The guide covers the checks that keep the system honest: field indicators and shims to prove the field, yoke lift tests, bath concentration by settling, and light intensity at the surface.
E709 sets no acceptance criteria. ASME Section V carries it as SE-709 and builds Article 7 on it, and AWS D1.1 and API 1104 name it for magnetic particle testing; each of those sets what an indication means. For aerospace parts, ASTM E1444 is the prescriptive practice and names its own SAE material specifications, including AMS 2641 for the oil vehicle.
In the glossary: Yoke and prods
Regulation
ASME Section V carries E709 as SE-709 and builds Article 7 on it; AWS D1.1 and API 1104 name it as the magnetic particle procedure. The acceptance criteria stay with each of those codes.
- Full title
- Standard Guide for Magnetic Particle Testing
- Issued by
- ASTM International
- Current edition
- ASTM E709, edition to confirm
- Applies to
- Surface and near-surface flaws in ferromagnetic parts and welds
- Techniques
- Yokes, prods, coils, cables, central conductors, and current through the part; dry or wet particles, visible or fluorescent
- Acceptance comes from
- The referencing code, such as AWS D1.1, API 1104, or the ASME construction code
- Aerospace twin
- ASTM E1444, a practice that prescribes rather than guides
- Personnel
- SNT-TC-1A or CP-189, as the employer's written practice sets
Who it's for
One record. Both sides of the job.
How inspection works
Methods under ASTM E709.
Who sets the procedure, who sets acceptance, and who may do the work, method by method.
| Method | Procedure | Acceptance | Certification |
|---|---|---|---|
| Magnetic particle (MT), yoke | ASTM E709, two directions per area | The code the job is built to | SNT-TC-1A or CP-189 Level II |
| Magnetic particle (MT), prods | ASTM E709 | The code the job is built to | SNT-TC-1A or CP-189 Level II |
| Magnetic particle (MT), coil, cable, or central conductor | ASTM E709 | The code the job is built to | SNT-TC-1A or CP-189 Level II |
Acceptance criteria
How a weld passes or fails.
E709 describes a valid magnetic particle test; the referencing code decides what passes.
- Each area is magnetized in two directions at roughly right angles, with the shots overlapping so no part of the surface is missed.
- Field strength and direction are shown adequate with a field indicator, shims, or a gaussmeter, or by the amperage rules the procedure adopts.
- Yokes pass a lift test, wet baths are checked for concentration and contamination, and UV-A or white light is measured at the surface.
- Particles are applied while the field is on for continuous techniques, and the surface is examined before the particles are disturbed.
- Indications are evaluated against the referencing code's criteria, relevant ones are recorded, and the part is demagnetized when the code or the next process requires it.
ASME Section V Article 7 adds its own written-procedure, lift-test, and demonstration requirements on top of SE-709.
A summary, not the code. Limits and exceptions are in the edition your job works to.
The report
What ASTM E709 reports have to carry.
The fields a Level III checks before signing. Miss one and the report comes back.
- Item, weld or part ID, material, and surface condition
- Procedure and revision, magnetization technique, current type, and amperage or yoke setting
- Particles: dry or wet, visible or fluorescent, and the bath concentration result if wet
- Field verification: indicator or shim result, and the two directions covered
- Light: UV-A intensity and ambient light for fluorescent, white light for visible
- Each relevant indication: location, length, and whether it's linear or rounded
- Acceptance criteria applied, the accept or reject result, and demagnetization if done
- Technician name, SNT-TC-1A or CP-189 level, and date
Where reports go wrong
The ASTM E709 mistakes that send a report back.
How the job's procedures come from your plan
The NDT reporting checklist: eight ways to get reports right the first time
One direction only.
A crack lying along the field doesn't show. Every area needs two directions, and the report should say so.
Field assumed, not shown.
An amperage setting proves nothing on its own. A field indicator or shim on the part proves the field is there and pointing the right way.
Arc strikes from prods.
Prods that aren't held firmly arc against the surface. On some materials that arc strike is a defect in its own right, and many codes restrict prods for that reason.
A guide read as a procedure.
E709 offers options. The written procedure has to pick the technique, the current, and the checks, and the referencing code may narrow them further.
Related codes
The codes around it.
FAQ
Questions.
Every other answer is on the FAQ page.
What is ASTM E709?
The ASTM guide to magnetic particle testing. It describes the magnetization techniques, the particles, the system checks, and demagnetization, and leaves acceptance to the referencing code.
What's the difference between ASTM E709 and E1444?
E709 is a guide: it describes options for general industry. E1444 is a practice: it prescribes the aerospace process, including the materials, the system checks, and their schedule.
Does ASTM E709 set acceptance criteria?
No. The code or specification that references it does, such as AWS D1.1, API 1104, or the ASME construction code.
Why does magnetic particle testing need two directions?
A flaw shows when it cuts across the magnetic field. One lying along the field leaks almost nothing, so each area is magnetized twice at roughly right angles.

See your own report rebuilt.
Book a 30-minute demo on one of your real reports.
Not ready to talk? The calculator works out hours and costs back from your own numbers.

