Code
ISO 17636: radiographic testing of welds.
The international standard for how welds are radiographed: Part 1 with film, Part 2 with digital detectors. Acceptance comes from ISO 10675.
What it covers
ISO 17636 in plain terms.
ISO 17636 sets how a weld is radiographed. It covers the arrangement of source, weld, and film or detector, the source-to-object distance, which radiation sources fit which thicknesses, and how image quality is proven.
It works in two classes. Class A is the basic technique; Class B is more sensitive and is used for critical work or where the application standard asks for it. The class sets the image quality that has to be reached.
Part 1 is for film. Part 2 is for digital radiography, with computed radiography plates or digital detector arrays, and sets equivalent requirements for image quality, including the detector's basic spatial resolution and signal-to-noise.
ISO 17636 doesn't accept or reject welds. Once the radiograph meets it, the indications are judged to ISO 10675.
In the glossary: Source-to-film distance
- Full title
- Non-destructive testing of welds — Radiographic testing
- Parts
- Part 1: X- and gamma-ray techniques with film · Part 2: with digital detectors
- Issued by
- ISO, adopted in Europe as EN ISO 17636
- Applies to
- Fusion-welded joints in metallic materials: plates and pipes
- Testing classes
- Class A, basic techniques · Class B, improved techniques
- Image quality
- Image quality indicators to ISO 19232
- Acceptance comes from
- ISO 10675, linked to the quality levels of ISO 5817
- Personnel
- Certified to ISO 9712
Who it's for
One record. Both sides of the job.
How inspection works
Methods under ISO 17636.
Who sets the procedure, who sets acceptance, and who may do the work, method by method.
| Method | Procedure | Acceptance | Certification |
|---|---|---|---|
| Radiographic (RT), film | ISO 17636-1, Class A or B | ISO 10675-1 for steel, nickel, and titanium; ISO 10675-2 for aluminum | ISO 9712 RT Level II |
| Radiographic (RT), digital | ISO 17636-2, Class A or B | ISO 10675-1 or -2 | ISO 9712 RT Level II |
Acceptance criteria
How a weld passes or fails.
ISO 17636 sets what makes a radiograph valid. Whether the weld passes is ISO 10675's job.
- The testing class, A or B, is chosen by the application standard or the contract.
- Image quality is proven with ISO 19232 indicators: the wire or step-hole value seen has to reach the class's requirement for the thickness.
- Film radiographs have to reach a minimum optical density; digital images a minimum normalized signal-to-noise and spatial resolution.
- Source-to-object distance has a minimum, set by the source size and the weld thickness, so the image stays sharp.
- A radiograph that misses any of these isn't interpreted. It's reshot.
A summary, not the code. Limits and exceptions are in the edition your job works to.
The report
What ISO 17636 reports have to carry.
The fields a Level III checks before signing. Miss one and the report comes back.
- Weld and component ID, material, and thickness
- ISO 17636 part and testing class
- Source or X-ray tube, focal spot size, and voltage or activity
- Film system class or digital detector type
- Technique: arrangement, source-to-object distance, exposure time, number of shots
- IQI type and the value seen; density or signal-to-noise achieved
- Indications and the ISO 10675 acceptance level applied
- Operator and interpreter names, ISO 9712 certification and date
Standards logic
Checked at capture, not after the report.
Where Weld Done holds a code's acceptance limits, each RT, VT, and UT indication is checked against them as it's entered. A rejected one shows the clause, the value, and the limit.
Standards logic →Where reports go wrong
The ISO 17636 mistakes that send a report back.
How the job's procedures come from your plan
The NDT reporting checklist: eight ways to get reports right the first time
No testing class on the report.
Class A and B need different image quality. Without the class, nobody can check the radiograph met it.
Digital treated like film.
Part 2 has its own requirements for signal-to-noise and resolution. A digital image judged by film density rules hasn't been qualified.
ISO 17636 cited as the acceptance standard.
It sets the technique. The weld is accepted to ISO 10675 at a stated level.
Related codes
The codes around it.
Edition referenced: ISO 17636-1:2022 and ISO 17636-2:2022. All codes and standards
FAQ
Questions.
Every other answer is on the FAQ page.
What's the difference between ISO 17636-1 and ISO 17636-2?
Part 1 covers radiography of welds with film. Part 2 covers the same with digital detectors, computed radiography plates or digital detector arrays.
What are testing classes A and B?
Class A is the basic technique and Class B the improved, more sensitive one. The application standard or contract chooses the class, and it sets the image quality required.
Does ISO 17636 have acceptance criteria?
No. It sets how to radiograph. Acceptance levels for the indications come from ISO 10675.

See your own report rebuilt.
Book a 30-minute demo on one of your real reports.
Not ready to talk? The calculator works out hours and costs back from your own numbers.