Code
ISO 17637: visual testing of welds.
The international standard for looking at a weld properly: the light, the distance, the angle, the tools, and what the report has to record.
What it covers
ISO 17637 in plain terms.
ISO 17637 makes visual testing a method with rules, not a glance. It sets the viewing conditions, the tools, when in the job the weld is looked at, and what gets recorded.
Direct visual testing needs enough light on the surface, the eye close enough and at a steep enough angle. Where that isn't possible, remote tools such as mirrors, borescopes, and cameras are used instead.
It covers the whole weld: the prepared joint before welding where required, the root and the passes during welding, and the finished weld and any repair after.
ISO 17637 doesn't accept or reject. The imperfections it finds are judged against the quality level the design names in ISO 5817.
- Full title
- Non-destructive testing of welds — Visual testing of fusion-welded joints
- Issued by
- ISO, adopted in Europe as EN ISO 17637
- Current edition
- ISO 17637:2016
- Applies to
- Fusion welds in metallic materials, as welded or after repair
- Testing
- Direct or remote visual testing, with gauges for size and profile
- Acceptance comes from
- ISO 5817 quality levels B, C, and D (ISO 10042 for aluminum)
- Personnel
- Trained and qualified for visual testing, often certified to ISO 9712
- Related standards
- ISO 17636 and ISO 17638 for radiography and magnetic particle testing of the same welds
Who it's for
One record. Both sides of the job.
How inspection works
Methods under ISO 17637.
Who sets the procedure, who sets acceptance, and who may do the work, method by method.
| Method | Procedure | Acceptance | Certification |
|---|---|---|---|
| Visual (VT), direct | ISO 17637 viewing conditions: illumination, distance, and angle | ISO 5817 at the quality level named | ISO 9712 VT, or as the specification requires |
| Visual (VT), remote | ISO 17637, with mirrors, borescopes, or cameras | ISO 5817 at the quality level named | ISO 9712 VT, or as the specification requires |
Acceptance criteria
How a weld passes or fails.
ISO 17637 sets how to look; ISO 5817 decides what passes. The quality level, B, C, or D, comes from the design or the application standard.
- The surface has to be lit well enough; the standard sets a minimum illumination and recommends more.
- For direct testing, the eye has to be within a set distance of the surface and at no less than a set angle to it.
- Weld size, profile, undercut, and misalignment are measured with gauges, not estimated.
- Each imperfection is named with its ISO 6520-1 reference number and judged against the ISO 5817 limits for the quality level.
- Cracks aren't acceptable at any quality level.
A summary, not the code. Limits and exceptions are in the edition your job works to.
The report
What ISO 17637 reports have to carry.
The fields a Level III checks before signing. Miss one and the report comes back.
- Weld and component ID, material, thickness, and welding process
- Stage of testing: preparation, during welding, or finished weld
- Direct or remote testing, the lighting and the aids used
- ISO 5817 quality level applied
- Each imperfection: ISO 6520-1 reference, location, and size
- Accept or reject per weld, and repairs
- Technician name, qualification, and date
Standards logic
Checked at capture, not after the report.
Where Weld Done holds a code's acceptance limits, each RT, VT, and UT indication is checked against them as it's entered. A rejected one shows the clause, the value, and the limit.
Standards logic →Where reports go wrong
The ISO 17637 mistakes that send a report back.
How the job's procedures come from your plan
The NDT reporting checklist: eight ways to get reports right the first time
No quality level on the report.
Without the ISO 5817 level, nobody can check whether an undercut or a profile was acceptable.
Sizes guessed, not gauged.
Weld size and undercut have numeric limits. A report without measured values can't be reviewed.
Poor light, no record of it.
If the viewing conditions aren't recorded, a missed crack can't be explained or prevented next time.
Related codes
The codes around it.
Edition referenced: ISO 17637:2016. All codes and standards
FAQ
Questions.
Every other answer is on the FAQ page.
What does ISO 17637 cover?
Visual testing of fusion-welded joints in metals: viewing conditions, equipment, when testing is done, and what the report records.
Does ISO 17637 have acceptance criteria?
No. Visual imperfections are judged against the quality levels of ISO 5817, or ISO 10042 for aluminum.
What viewing conditions does ISO 17637 set?
A minimum light level on the surface, a maximum eye-to-surface distance and a minimum viewing angle for direct testing. Remote tools are used where those can't be met.

See your own report rebuilt.
Book a 30-minute demo on one of your real reports.
Not ready to talk? The calculator works out hours and costs back from your own numbers.