ASTM E2698: radiographic examination using digital detector arrays.
The ASTM practice for radiography with a digital detector array in place of film: how the detector is qualified and calibrated, how image quality is proven, and how images are processed and stored.
What it covers
ASTM E2698 in plain terms.
E2698 is the digital detector array practice that sits beside the film guide, ASTM E94. It covers the detector, the X-ray or gamma-ray source, the technique, image quality, image processing, and how the image is kept.
The detector has to be qualified before it goes to work. The manufacturer characterizes it to ASTM E2597, and the user checks it on a schedule to ASTM E2737 so that drift, dead pixels, and burn-in don't creep into production images. Each session starts with offset and gain calibration and a current bad pixel map.
Image quality is proven on the image, the way it is on film. A hole-type or wire IQI shows the contrast sensitivity, a duplex wire gauge to ASTM E2002 shows the basic spatial resolution, and the signal-to-noise ratio is measured in the area of interest. Processing is limited to what the written procedure allows, and the stored image keeps a record of every filter applied, because a filter can hide a flaw as easily as sharpen one.
E2698 sets no accept or reject limits. The construction code does: ASME Section V Article 2 carries ASME's own requirements for digital techniques, API 1104 allows digital detectors in its radiographic section, and ISO 17636-2 is the ISO counterpart for welds.
In the glossary: DR and CR
- Full title
- Standard Practice for Radiographic Examination Using Digital Detector Arrays
- Issued by
- ASTM International
- Current edition
- ASTM E2698, edition to confirm
- Applies to
- Radiography of welds, castings, and other parts with a digital detector array (DDA) instead of film
- Detector qualification
- Manufacturer characterization to ASTM E2597; in-service stability checks to ASTM E2737
- Image quality
- Hole-type or wire IQIs to ASTM E1025 or E747; duplex wire gauge to ASTM E2002 for spatial resolution
- Acceptance comes from
- The construction code or the purchase specification, not E2698
- Personnel
- SNT-TC-1A or CP-189 RT Level II, with the digital training the written practice requires
Who it's for
One record. Both sides of the job.
How inspection works
Methods under ASTM E2698.
Who sets the procedure, who sets acceptance, and who may do the work, method by method.
| Method | Procedure | Acceptance | Certification |
|---|---|---|---|
| Radiographic (RT), digital detector array | ASTM E2698, as the written procedure applies it | The code the job is built to: API 1104, ASME Section VIII, or the purchase specification | SNT-TC-1A or CP-189 RT Level II, plus radiation safety |
Acceptance criteria
How a weld passes or fails.
E2698 sets no acceptance criteria for the part. Its controls decide whether the digital image is fit to be read.
- The detector is characterized by the manufacturer and checked by the user on the schedule the procedure sets, with the results kept.
- Offset and gain calibration and the bad pixel map are current for the session, and bad pixels aren't clustered where a flaw would sit.
- Contrast sensitivity is proven with the IQI the procedure names, and the required hole or wire is visible in the image.
- Basic spatial resolution and signal-to-noise ratio in the area of interest reach the values the procedure or the referencing code requires.
- Image processing stays within what the procedure allows, and the stored image carries its processing history, with the unprocessed data kept where the code requires it.
- Once the image passes those checks, the indications are judged to the construction code's acceptance criteria.
Digital images are easy to improve on screen. The record has to show that what the interpreter saw is what the detector captured, within the allowed processing.
A summary, not the code. Limits and exceptions are in the edition your job works to.
The report
What ASTM E2698 reports have to carry.
The fields a Level III checks before signing. Miss one and the report comes back.
- Part or weld ID, material, and thickness
- Detector make, model, serial, and the date of its last stability check
- Source or X-ray kV, source-to-detector distance, magnification, and frames averaged
- Calibration: offset, gain, and bad pixel map references for the session
- IQI type and the hole or wire seen; basic spatial resolution and signal-to-noise measured
- Processing applied, filter by filter, and the file name and format of the stored image
- Each indication, its location, and the call against the named acceptance code
- Radiographer and interpreter names, certification level, and signature
Where reports go wrong
The ASTM E2698 mistakes that send a report back.
How the job's procedures come from your plan
The NDT reporting checklist: eight ways to get reports right the first time
Film rules applied to a digital image.
There is no density on a detector array image. Signal-to-noise, spatial resolution, and the IQI prove the image, and a report that quotes density hasn't checked them.
Processing with no record.
A filtered image with no processing history can't be trusted or repeated. The procedure says what is allowed, and the record shows what was done.
Detector checks lapsed.
A detector that missed its stability check may have drifted or grown dead pixels. Every image made since the last good check is in question.
E2698 named as the acceptance standard.
It is a practice for making the image. The construction code decides what the indications mean.
Related codes
The codes around it.
FAQ
Questions.
Every other answer is on the FAQ page.
What is ASTM E2698?
ASTM's practice for radiography with a digital detector array: detector qualification and calibration, technique, image quality, processing, and storage. It sets no acceptance criteria.
What is a digital detector array?
A flat-panel or linear detector that converts X-rays or gamma rays straight to a digital image, with no film and no plate reader. E2698 covers that case; computed radiography with phosphor plates has its own practice, ASTM E2033.
What replaces film density in digital radiography?
Signal-to-noise ratio and basic spatial resolution, measured in the image, together with the IQI. E2698 sets how they're measured; the referencing code sets what they have to reach.
How does ASTM E2698 relate to ISO 17636-2?
Both cover radiography of welds with digital detectors. ISO 17636-2 is the usual reference in Europe; E2698 is the practice North American procedures cite.