Code
ASTM E94: radiographic examination with industrial film.
The ASTM guide for how a weld or casting is radiographed on film: the technique, the film and screens, the proof of image quality, and the viewing conditions, with acceptance left to the construction code.
What it covers
ASTM E94 in plain terms.
E94 is a guide to film radiography. It covers the choice of source and energy for the thickness, the arrangement of source, part, and film, single-wall and double-wall techniques, source-to-film distance, and how geometric unsharpness is kept within the limit the job sets.
It classifies film systems by speed and granularity through ASTM E1815, and says when lead or fluorescent screens are used and how they're kept clean and in contact with the film. Processing follows ASTM E999, and the processed film has to reach the density range the procedure names, with no artifacts that could hide or mimic a flaw.
Image quality is proven on the film itself. A hole-type IQI to ASTM E1025 or a wire IQI to ASTM E747 goes on the source side, or on the film side with a lead letter F, and the radiograph counts only if the required hole or wire shows. Viewing conditions matter too: a viewer bright enough for the density, low surrounding light, and a calibrated densitometer at hand.
E94 doesn't accept or reject anything. The code the job is built to, such as API 1104 for pipeline girth welds or ASME Section VIII through Section V Article 2, decides what an indication means. Procedures and purchase orders cite E94 as the technique reference, and its digital counterpart is ASTM E2698.
In the glossary: Film density · Source-to-film distance
- Full title
- Standard Guide for Radiographic Examination Using Industrial Radiographic Film
- Issued by
- ASTM International
- Current edition
- ASTM E94/E94M, edition to confirm
- Applies to
- Film radiography of welds, castings, and other metal parts with X-ray or gamma-ray sources
- Image quality
- Hole-type IQIs to ASTM E1025 or wire IQIs to ASTM E747
- Film systems
- Classified to ASTM E1815; processing controlled to ASTM E999
- Acceptance comes from
- The construction code or the purchase specification, not E94
- Personnel
- SNT-TC-1A or CP-189 RT Level II, plus radiation safety
Who it's for
One record. Both sides of the job.
How inspection works
Methods under ASTM E94.
Who sets the procedure, who sets acceptance, and who may do the work, method by method.
| Method | Procedure | Acceptance | Certification |
|---|---|---|---|
| Radiographic (RT), film | ASTM E94/E94M, as the written procedure applies it | The code the job is built to: API 1104, ASME Section VIII, or AWS D1.1 | SNT-TC-1A or CP-189 RT Level II, plus radiation safety |
Acceptance criteria
How a weld passes or fails.
E94 sets no accept or reject limits. What it sets decides whether the film can be read at all.
- The source energy and the technique suit the material and thickness, so the film has enough contrast to show the flaws the code cares about.
- Geometric unsharpness, set by the source size, the source-to-object distance, and the object-to-film distance, stays within the limit the procedure or code names.
- The IQI is the right type and size for the thickness, is placed as the standard says, and the required hole or wire is visible on the processed film.
- Film density falls inside the procedure's range across the area of interest, measured with a calibrated densitometer.
- The film is free of processing artifacts, screen marks, and scratches in the area of interest, and is viewed on a viewer with enough luminance in subdued light.
- Once the film passes those checks, the indications are judged to the construction code's acceptance criteria.
A report that cites E94 alone has no acceptance basis. It has to name the code whose criteria were applied.
A summary, not the code. Limits and exceptions are in the edition your job works to.
The report
What ASTM E94 reports have to carry.
The fields a Level III checks before signing. Miss one and the report comes back.
- Part or weld ID, material, and thickness
- Technique: source or X-ray kV, focal spot or source size, source-to-film distance, and single-wall or double-wall shot
- Film system class, screens, and the number of films per shot
- IQI type, designation, placement side, and the hole or wire seen
- Density measured in the area of interest
- Processing: manual or automatic, and the processing control reference
- Each indication, its location, and the call against the named acceptance code
- Radiographer and interpreter names, certification level, and signature
Where reports go wrong
The ASTM E94 mistakes that send a report back.
How the job's procedures come from your plan
The NDT reporting checklist: eight ways to get reports right the first time
E94 named as the acceptance standard.
E94 is a guide to technique. Without the construction code on the report, the accept or reject call has no basis.
Film-side IQI not marked.
A film-side IQI has to be identified as one. Read as a source-side IQI, it overstates the sensitivity the shot reached.
Density taken in the wrong place.
Density is checked through the weld or the area of interest, not the base metal beside it. A film that reads right off to the side can still be unreadable where it matters.
Geometry not recorded.
Without the source size and the distances, nobody can confirm unsharpness stayed within the limit, and the shot can't be repeated the same way.
Related codes
The codes around it.
FAQ
Questions.
Every other answer is on the FAQ page.
What is ASTM E94?
ASTM's guide to radiography on industrial film: source selection, technique, film systems, screens, image quality indicators, density, and viewing. It sets no acceptance criteria.
Does ASTM E94 have acceptance criteria?
No. It describes how to make and read a film radiograph. The code the part is built to decides which indications are acceptable.
What's the difference between ASTM E94 and ASTM E2698?
E94 covers film. E2698 covers digital detector arrays, with its own requirements for detector calibration and image quality.
What IQIs does ASTM E94 use?
Hole-type IQIs to ASTM E1025 or wire IQIs to ASTM E747, selected by the thickness of the part and placed on the source side where possible.
Is ASTM E94 the same as ISO 17636-1?
They cover the same ground. ISO 17636-1 is the ISO standard for film radiography of welds and the usual reference in Europe. E94 is the ASTM guide North American procedures cite.

See your own report rebuilt.
Book a 30-minute demo on one of your real reports.
Not ready to talk? The calculator works out hours and costs back from your own numbers.