ASTM E747: wire image quality indicators for radiography.

The ASTM standard that defines the wire image quality indicator, its wire sizes, its material groups, and its identification, so that a radiograph can prove the sensitivity it reached.

Design, Manufacture and Material Grouping Classification of Wire Image Quality Indicators · ASTM International

What it covers

ASTM E747 in plain terms.

E747 doesn't tell anyone how to radiograph. It defines the tool that proves a radiograph was sensitive enough: a set of wires of known diameter and known material, laid on the part so the image shows which wire can still be seen.

The wires come in four sets, A to D, each of six wires stepping from fine to coarse, and each set is identified in the image by lead letters and a number for its material group. The group matters because an IQI absorbs radiation like the metal it's made from. A set has to match the part's material group, or come from a group that absorbs less radiation, so the sensitivity it shows is conservative.

The job's code picks the wire that has to show. API 1104, ASME Section V Article 2, and the ASTM practices E94 and E2698 each tell the radiographer which set to place for a given thickness and which wire is the essential one. The radiograph is valid only when that wire is visible in the area of interest.

ISO 19232-1 is the ISO wire IQI. Its wires are numbered differently and have different diameters, so a wire number under one standard isn't the same wire under the other. A report has to say which IQI standard the wire belongs to, or the sensitivity it claims can't be checked.

In the glossary: IQI

Full title
Standard Practice for Design, Manufacture and Material Grouping Classification of Wire Image Quality Indicators (IQI) Used for Radiology
Issued by
ASTM International
Current edition
ASTM E747, edition to confirm
Applies to
Wire IQIs placed on the part during a film or digital shot to prove radiographic sensitivity
Wire sets
Sets A, B, C, and D, each of six wires, from finest to coarsest
Material groups
Groups from light alloys to heavy alloys, so the IQI absorbs radiation like the part under it
Used by
API 1104, ASME Section V Article 2 (as SE-747), ASTM E94, and ASTM E2698
ISO counterpart
ISO 19232-1 wire IQIs, with different wire diameters and numbering

Who it's for

One record. Both sides of the job.

How inspection works

Methods under ASTM E747.

Who sets the procedure, who sets acceptance, and who may do the work, method by method.

MethodProcedureAcceptanceCertification
Radiographic (RT), film or digitalASTM E94 or ASTM E2698, with the IQI to ASTM E747The code the job is built to: API 1104, ASME Section VIII, or AWS D1.1SNT-TC-1A or CP-189 RT Level II

Acceptance criteria

How a weld passes or fails.

E747 accepts or rejects nothing. It makes the IQI itself trustworthy, so the sensitivity a radiograph claims can be believed.

  • Each wire is made to the diameter and tolerance the standard sets, in the material its group names.
  • The set is marked with lead letters and a group number that show in the image, so the reader knows which set and which material was used.
  • The set's material group matches the part, or absorbs less radiation than it, so the sensitivity shown is conservative.
  • The referencing code names the essential wire for the thickness, and the radiograph is read only when that wire is visible.
  • Damaged, bent, or corroded sets are retired, because a wire that no longer meets its tolerance proves nothing.

The IQI tells the reader how small a change in thickness the radiograph can show. It never tells the reader whether the weld is acceptable.

A summary, not the code. Limits and exceptions are in the edition your job works to.

The report

What ASTM E747 reports have to carry.

The fields a Level III checks before signing. Miss one and the report comes back.

  • IQI standard: ASTM E747, with the set letter and material group number
  • Essential wire required by the code for the thickness, and the wire actually seen
  • IQI placement: source side or film side, and where on the part
  • Number of IQIs per shot, where the code requires more than one
  • Material and thickness the selection was based on, including any shim
  • The code that set the essential wire: API 1104, ASME Section V, or the purchase specification

How Weld Done builds your NDT report template

  1. Wire number without the standard.

    An ASTM wire 10 and an ISO W10 are different wires. A number alone can't be checked against the required sensitivity.

  2. Wrong material group.

    A set that absorbs more than the part makes the radiograph look more sensitive than it is. The group number in the image gives it away to anyone who looks.

  3. A worn set still in use.

    Wires bend and corrode. Once a set drifts out of tolerance, every radiograph it was placed on carries a sensitivity claim that can't be defended.

FAQ

Questions.

Every other answer is on the FAQ page.

Visit FAQ
What is ASTM E747?

The ASTM standard that defines wire image quality indicators: wire diameters, set letters, material groups, and identification. It makes the IQI trustworthy; the referencing code decides which wire has to show.

What is an essential wire?

The finest wire that has to be visible on the radiograph for the thickness being shot. The construction code or specification names it, by set and wire number, and the radiograph is read only if it shows.

What's the difference between a wire IQI and a hole-type IQI?

A wire IQI shows sensitivity by the finest wire visible. A hole-type IQI to ASTM E1025 is a plaque of set thickness with drilled holes, and shows it by the hole visible. Codes usually allow either.

Is ASTM E747 the same as ISO 19232?

No. ISO 19232-1 defines the ISO wire IQI with its own diameters and numbering. The two aren't interchangeable, and the report has to say which one was used.