Code

ISO 16809: ultrasonic thickness measurement.

The international standard for measuring wall thickness with ultrasound, used wherever an owner needs to know how much metal is left.

Non-destructive testing — Ultrasonic thickness measurement · ISO · ISO 16809:2017

What it covers

ISO 16809 in plain terms.

ISO 16809 sets how wall thickness is measured with ultrasound: the instrument, the probe, the calibration, the coupling, and the record. It applies to metals and other materials that carry ultrasound well enough to return a back-wall echo, on plate, pipe, vessels, and castings, new or in service.

It describes three measuring modes by which echoes the instrument times between, and three kinds of instrument: a dedicated gauge with a numerical readout, a gauge with an A-scan display, and a flaw detector used for thickness. The A-scan matters on corroded metal, because a gauge that shows only a number can lock onto the wrong echo over pitting, a lamination, or a coating.

Calibration is on reference blocks or step wedges of the same material, and the sound velocity is set for that material. Hot surfaces need a high-temperature couplant and a velocity correction; coatings need an echo-to-echo mode or a measured allowance; a rough or pitted surface needs preparation and a probe that suits it.

ISO 16809 does not set a minimum wall. The owner's inspection code does: API 510 for pressure vessels, API 570 for piping, and API 653 for storage tanks in North America, each with its own thickness monitoring locations and corrosion-rate rules. The weld standards ISO 17640 and ISO 11666 use the same instruments for a different question, the soundness of the weld.

Regulation

In Europe the standard is EN ISO 16809; in North America the in-service codes API 510, API 570, and API 653 lean on ASTM E797 and the owner's written procedure for the same measurement.

Full title
Non-destructive testing — Ultrasonic thickness measurement
Issued by
ISO, adopted in Europe as EN ISO 16809
Current edition
ISO 16809:2017
Applies to
Wall thickness of metals and other low-attenuation materials, new or in service, by pulse-echo contact testing
Instruments
Dedicated gauges with a numerical readout, gauges with an A-scan, and flaw detectors
Acceptance comes from
The owner's inspection code or the design, not ISO 16809
North American counterpart
ASTM E797, adopted in ASME Section V
Personnel
ISO 9712 UT, or a limited certification for thickness measurement where the scheme allows it

Who it's for

One record. Both sides of the job.

How inspection works

Methods under ISO 16809.

Who sets the procedure, who sets acceptance, and who may do the work, method by method.

MethodProcedureAcceptanceCertification
Ultrasonic (UT)ISO 16809The owner's inspection code: API 510, API 570, or API 653 minimum thickness, or the design's corrosion allowanceISO 9712 UT Level II, or a limited UT certification for thickness measurement

Acceptance criteria

How a weld passes or fails.

ISO 16809 makes the reading trustworthy; the inspection code decides whether the wall is thick enough.

  • The instrument is calibrated on a reference of the same material before the survey and checked again after it, with the velocity recorded.
  • The measuring mode and the instrument are matched to the surface: an A-scan is used where corrosion, pitting, or a coating could mislead a numerical gauge.
  • The surface is prepared, the couplant suits the temperature, and a velocity correction is applied on hot metal.
  • Each reading is taken at a marked location so the next survey repeats it, and the minimum found at that location is what goes on the record.
  • The reading is compared with earlier surveys and the minimum wall from the inspection code or the design, and that comparison is the owner's call.

A summary, not the code. Limits and exceptions are in the edition your job works to.

The report

What ISO 16809 reports have to carry.

The fields a Level III checks before signing. Miss one and the report comes back.

  • Component ID, material, nominal thickness, and surface temperature
  • Instrument, probe, couplant, and measuring mode
  • Calibration reference, velocity used, and the before-and-after checks
  • Each location: its ID or grid position, the reading, and the minimum found
  • Surface condition and coating, with how the coating was handled
  • Minimum wall or acceptance reference from the inspection code or the design
  • Operator name, certification, and date

How Weld Done builds your NDT report template

  1. No A-scan on corroded metal.

    A numerical gauge can read a coating, a lamination, or the far side of a pit as the back wall. The record has to show which instrument was used and why it was trusted.

  2. Velocity not corrected for temperature.

    Sound slows in hot steel, so an uncorrected reading on a live line reads thick. The surface temperature and the correction belong on the record.

  3. Locations not repeatable.

    A corrosion rate is a difference between two surveys at the same spot. A reading with no marked location cannot be compared with the next one.

Related codes

The codes around it.

Edition referenced: ISO 16809:2017. All codes and standards

FAQ

Questions.

Every other answer is on the FAQ page.

Visit FAQ
What does ISO 16809 cover?

How wall thickness is measured with ultrasound: the instruments, the calibration, the coupling and surface preparation, the effect of temperature and coatings, and what the record has to carry.

Does ISO 16809 set a minimum wall thickness?

No. The minimum comes from the owner's inspection code, such as API 510, API 570, or API 653, or from the design's corrosion allowance.

What is the difference between ISO 16809 and ASTM E797?

Both set how ultrasonic thickness measurement is done. ISO 16809 is the international standard, adopted in Europe as EN ISO 16809; ASTM E797 is the North American practice, adopted in ASME Section V.

Can a thickness gauge be used on a corroded surface?

Yes, with care. ISO 16809 expects an A-scan display where pitting, a lamination, or a coating could mislead a gauge that only shows a number, and it expects the surface to be prepared first.

See your own report rebuilt.

Book a 30-minute demo on one of your real reports.

Not ready to talk? The calculator works out hours and costs back from your own numbers.