Code
API 570: inspecting process piping in service.
The code for inspecting the piping in refineries and plants once it's running: where to look, how often, and how to repair it.
What it covers
API 570 in plain terms.
API 570 does for piping what API 510 does for vessels. ASME B31.3 builds the piping; API 570 governs its inspection, rating, repair, and alteration once it's in service.
Piping is sorted into classes by the consequence of a leak. The class sets how often thickness and external inspections are due, and a risk-based program can set them instead.
Most piping damage happens in predictable places, so the code points inspection at them: injection and mix points, dead legs, soil-to-air interfaces, and corrosion under insulation.
As with vessels, wall thickness is measured at condition monitoring locations, corrosion rates come from the history, and remaining life sets the next inspection.
Where it’s used: Oil, gas, and petrochemical
In the glossary: In-service inspection · Thickness gauging
- Full title
- Piping Inspection Code: In-service Inspection, Rating, Repair, and Alteration of Piping Systems
- Issued by
- American Petroleum Institute (API)
- Applies to
- Metallic and fiberglass process piping in service in refineries, petrochemical, and chemical plants
- Required by
- Owners' mechanical integrity programs
- Inspector
- An API 570 authorized piping inspector
- Built to
- ASME B31.3, or the code the piping was built to
- Key ideas
- Piping classes · condition monitoring locations · injection points and dead legs · corrosion under insulation
- Related codes
- API 510 for vessels · API 653 for tanks · API 574 for piping inspection practice
Who it's for
One record. Both sides of the job.
How inspection works
Methods under API 570.
Who sets the procedure, who sets acceptance, and who may do the work, method by method.
| Method | Procedure | Acceptance | Certification |
|---|---|---|---|
| Visual (VT) | External visual inspection, including insulation, supports, and coating | The inspector's assessment against API 570 | API 570 authorized piping inspector |
| Ultrasonic thickness (UT) | Readings at condition monitoring locations on each circuit | Minimum required thickness; remaining life per API 570 | UT Level II, or a qualified thickness technician |
| Profile radiography (RT) | Profile shots for wall loss, including under insulation | Measured wall against minimum required thickness | RT Level II, plus radiation safety |
| Advanced UT (guided wave, corrosion mapping) | Screening and mapping per the owner's procedure | Follow-up measurement and fitness-for-service | Technique-specific qualification |
| Repair welds (RT or UT) | ASME Section V | ASME B31.3 criteria for the repair | Level II in the method |
Acceptance criteria
How a weld passes or fails.
Like API 510, API 570 decides whether piping stays in service and until when, not whether one weld passes.
- Measured thickness is compared with the minimum required thickness for the line's pressure and structural loads.
- Corrosion rates, long-term and short-term, come from the thickness history at each location.
- Remaining life sets the next thickness inspection, inside the maximum interval for the piping class.
- Damage beyond the simple rules is assessed for fitness for service, usually to API 579-1/ASME FFS-1.
- Repairs and alterations follow the construction code, with the inspector's approval.
A summary, not the code. Limits and exceptions are in the edition your job works to.
The report
What API 570 reports have to carry.
The fields a Level III checks before signing. Miss one and the report comes back.
- Circuit and line ID, piping class, service, and design data
- Inspection type and the inspection plan it follows
- Thickness readings at each location, with previous readings
- Corrosion rates, minimum required thickness and remaining life
- Findings at injection points, dead legs, supports, and insulation
- Repairs, temporary repairs and their follow-up dates
- Recommendations and next inspection dates
- Inspector name, API 570 certification number and signature
Where reports go wrong
The API 570 mistakes that send a report back.
How the job's procedures come from your plan
The NDT reporting checklist: eight ways to get reports right the first time
The circuit isn't the same circuit.
Locations renamed or moved between inspections break the thickness history, and the corrosion rate with it.
Insulation left on.
Corrosion under insulation is invisible from outside. A report that skips the susceptible areas misses the damage the code tells you to find.
A temporary repair that became permanent.
Clamps and sleeves need a follow-up date. Without it in the record, they stay on long past their life.
Free-text findings.
Long narrative reports with nothing checking the numbers let a wrong reading or rate through to the next inspection plan.
FAQ
Questions.
Every other answer is on the FAQ page.
What does API 570 cover?
In-service inspection, rating, repair, and alteration of process piping in refineries and chemical plants. New piping is built to ASME B31.3; API 570 takes over in service.
What are API 570 piping classes?
Classes that sort piping by the consequence of a leak. The class sets the maximum intervals for thickness and external inspections, unless a risk-based program sets them.
What is a condition monitoring location?
A fixed point on a piping circuit where thickness is measured every inspection, so readings can be compared and a corrosion rate worked out.
What's the difference between API 570 and API 574?
API 570 is the code that sets the requirements. API 574 is a recommended practice that explains how to inspect piping components.

See your own report rebuilt.
Book a 30-minute demo on one of your real reports.
Not ready to talk? The calculator works out hours and costs back from your own numbers.