Code

API 570: inspecting process piping in service.

The code for inspecting the piping in refineries and plants once it's running: where to look, how often, and how to repair it.

Piping Inspection Code · American Petroleum Institute

What it covers

API 570 in plain terms.

API 570 does for piping what API 510 does for vessels. ASME B31.3 builds the piping; API 570 governs its inspection, rating, repair, and alteration once it's in service.

Piping is sorted into classes by the consequence of a leak. The class sets how often thickness and external inspections are due, and a risk-based program can set them instead.

Most piping damage happens in predictable places, so the code points inspection at them: injection and mix points, dead legs, soil-to-air interfaces, and corrosion under insulation.

As with vessels, wall thickness is measured at condition monitoring locations, corrosion rates come from the history, and remaining life sets the next inspection.

Where it’s used: Oil, gas, and petrochemical

In the glossary: In-service inspection · Thickness gauging

Full title
Piping Inspection Code: In-service Inspection, Rating, Repair, and Alteration of Piping Systems
Issued by
American Petroleum Institute (API)
Applies to
Metallic and fiberglass process piping in service in refineries, petrochemical, and chemical plants
Required by
Owners' mechanical integrity programs
Inspector
An API 570 authorized piping inspector
Built to
ASME B31.3, or the code the piping was built to
Key ideas
Piping classes · condition monitoring locations · injection points and dead legs · corrosion under insulation
Related codes
API 510 for vessels · API 653 for tanks · API 574 for piping inspection practice

Who it's for

One record. Both sides of the job.

How inspection works

Methods under API 570.

Who sets the procedure, who sets acceptance, and who may do the work, method by method.

MethodProcedureAcceptanceCertification
Visual (VT)External visual inspection, including insulation, supports, and coatingThe inspector's assessment against API 570API 570 authorized piping inspector
Ultrasonic thickness (UT)Readings at condition monitoring locations on each circuitMinimum required thickness; remaining life per API 570UT Level II, or a qualified thickness technician
Profile radiography (RT)Profile shots for wall loss, including under insulationMeasured wall against minimum required thicknessRT Level II, plus radiation safety
Advanced UT (guided wave, corrosion mapping)Screening and mapping per the owner's procedureFollow-up measurement and fitness-for-serviceTechnique-specific qualification
Repair welds (RT or UT)ASME Section VASME B31.3 criteria for the repairLevel II in the method

Acceptance criteria

How a weld passes or fails.

Like API 510, API 570 decides whether piping stays in service and until when, not whether one weld passes.

  • Measured thickness is compared with the minimum required thickness for the line's pressure and structural loads.
  • Corrosion rates, long-term and short-term, come from the thickness history at each location.
  • Remaining life sets the next thickness inspection, inside the maximum interval for the piping class.
  • Damage beyond the simple rules is assessed for fitness for service, usually to API 579-1/ASME FFS-1.
  • Repairs and alterations follow the construction code, with the inspector's approval.

A summary, not the code. Limits and exceptions are in the edition your job works to.

The report

What API 570 reports have to carry.

The fields a Level III checks before signing. Miss one and the report comes back.

  • Circuit and line ID, piping class, service, and design data
  • Inspection type and the inspection plan it follows
  • Thickness readings at each location, with previous readings
  • Corrosion rates, minimum required thickness and remaining life
  • Findings at injection points, dead legs, supports, and insulation
  • Repairs, temporary repairs and their follow-up dates
  • Recommendations and next inspection dates
  • Inspector name, API 570 certification number and signature

How Weld Done builds your NDT report template

  1. The circuit isn't the same circuit.

    Locations renamed or moved between inspections break the thickness history, and the corrosion rate with it.

  2. Insulation left on.

    Corrosion under insulation is invisible from outside. A report that skips the susceptible areas misses the damage the code tells you to find.

  3. A temporary repair that became permanent.

    Clamps and sleeves need a follow-up date. Without it in the record, they stay on long past their life.

  4. Free-text findings.

    Long narrative reports with nothing checking the numbers let a wrong reading or rate through to the next inspection plan.

FAQ

Questions.

Every other answer is on the FAQ page.

Visit FAQ
What does API 570 cover?

In-service inspection, rating, repair, and alteration of process piping in refineries and chemical plants. New piping is built to ASME B31.3; API 570 takes over in service.

What are API 570 piping classes?

Classes that sort piping by the consequence of a leak. The class sets the maximum intervals for thickness and external inspections, unless a risk-based program sets them.

What is a condition monitoring location?

A fixed point on a piping circuit where thickness is measured every inspection, so readings can be compared and a corrosion rate worked out.

What's the difference between API 570 and API 574?

API 570 is the code that sets the requirements. API 574 is a recommended practice that explains how to inspect piping components.

See your own report rebuilt.

Book a 30-minute demo on one of your real reports.

Not ready to talk? The calculator works out hours and costs back from your own numbers.