A worker in a hard hat and yellow gloves at a machine's hydraulic lines and fittings

Method

Ultrasonic testing for weld inspection.

UT sends high-frequency sound into the weld and listens for what comes back from flaws inside it. Here's how it's done, which codes set its rules, who can perform it, and what a UT report has to carry.

UT
Where it works
Welds and base metal thick enough to scan
Procedure
ASME Section V, Article 4; ASTM E164
Acceptance
The code the job is built to
Inspector
Certified to SNT-TC-1A or CP-189

Codes

How it works

Ultrasonic testing in plain terms.

A probe sends sound into the weld through a couplant. Sound that hits a flaw reflects back, and the instrument shows how deep it is and how strong the echo is, against a reference level set on a calibration block.

Angle (shear wave) probes cover the weld's volume and size what they find; straight probes measure wall thickness. There's no radiation and no image to keep, so the report is the record of the scan: what was calibrated, what was covered, and what was found.

In the glossary: Calibration block · Couplant · Reference level · Sensitivity · Thickness gauging

Techniques

Straight beam, angle beam, and sizing.

Straight beam testing sends sound straight into the metal. It measures wall thickness and checks the base metal beside the weld for laminations before the angle beam scan, since a lamination can block or redirect the sound.

Angle beam testing uses shear waves at set angles, usually 45, 60, or 70 degrees, to cover the weld from the side. The probe is moved back and forth and along the weld so the beam passes through the whole weld volume and the heat-affected zone.

Shear wave UT sizes what it finds. Length is measured by moving the probe until the echo drops by a set amount, such as 6 dB. Height can be measured with the same drop method or with tip diffraction, which times the echoes from a flaw's top and bottom edges. Amplitude is compared with a reference, either a distance-amplitude correction (DAC) curve from side-drilled holes or, under AWS D1.1, an indication rating in decibels.

Calibration.

The instrument and probe are calibrated on reference blocks before the scan: an IIW-type block for range, angle, and probe exit point, and a calibration block of the same material and thickness range for the reference level. The calibration is checked again at set intervals and at the end of the scan. If it has drifted, the welds scanned since the last good check are rescanned.

Strengths and limits

Where UT works and where it stops.

There's no radiation, it needs access from one side only, and it sizes what it finds: a flaw's depth and length, and, with shear wave sizing techniques, its height. It's good at finding planar flaws like cracks and lack of fusion.

Conventional UT leaves no image. The report is the record of the scan, so the calibration and the coverage have to be written down. Results depend on the operator, and coarse-grained or thin material can be hard to read.

Who can perform UT

Who can perform UT.

UT inspectors are certified to SNT-TC-1A or CP-189, like inspectors for every other method. A Level II sets up and calibrates the equipment, evaluates indications, and signs the report. Thickness measurement can be a limited certification, so an inspector certified only for thickness readings can't evaluate welds. Some codes and clients also require a practical demonstration on samples with known flaws.

The report

What a UT report has to carry.

The fields a Level III checks before signing, in the order the report runs. Miss one and the report comes back.

The job

  • Job, client, and location
  • Drawing or line number
  • Weld ID and welder ID

Procedure and material

  • WPS reference
  • Material, diameter, and wall thickness
  • Governing code and the acceptance criteria applied

Technique and equipment

  • Instrument, and probe frequency and angle
  • Couplant
  • Calibration block and reference level
  • Scan coverage and the surfaces scanned from
  • Calibration checks before and after

Results

  • Each indication: location, depth, length, echo amplitude against the reference, and the accept or reject call
  • Final disposition per weld
  • Repair tracking

Sign-off

  • Technician name, cert level, and signature
  • Reviewer sign-off and date

How Weld Done builds your NDT report template

Standards logic

Checked at capture, not after the report.

Each UT indication is checked against the acceptance limits as it's entered. A rejected one shows the clause, the value, and the limit.

Standards logic →

Where reports go wrong

What sends a UT report back.

Calibration not recorded
No calibration block or reference level on the report, so the echo heights it quotes can't be checked.
Coverage unclear
A report that doesn't say which surfaces and angles were scanned, so nobody can tell whether the whole weld was covered.
No check at the end
A calibration checked at the start but not after the scan, so drift during the job goes unnoticed.

The NDT reporting checklist: eight ways to get reports right the first time

FAQ

Questions.

Every other answer is on the FAQ page.

Visit FAQ
What does an ultrasonic testing report have to include?

The job and weld, the procedure and material, the governing code and acceptance criteria, the instrument and probes, the couplant, the calibration block and reference level, the scan coverage, each indication with its location, size, amplitude, and call, and the technician's and reviewer's signatures.

UT or RT: which does the code accept?

Many codes accept either for inspecting inside the weld. The code the job is built to, and the client's specification, decide.

Can conventional UT size a flaw's height?

Yes. Shear wave UT measures height with a decibel-drop method or with tip diffraction, as well as measuring length and depth. PAUT and TOFD size flaws too; they add coverage and a stored record rather than the ability to size.

What's the difference between UT and PAUT?

Conventional UT uses a single-element probe at a fixed angle, moved by hand, and the report is the record. PAUT uses a probe with many elements that sweeps a range of angles from one position and saves an encoded scan that can be reopened. Both locate and size flaws, and PAUT is certified as a UT technique.

Can we download a UT report template?

Not yet. Until there's a sample report we can publish, this page lists everything the report has to carry.

A summary, not the code: procedures and limits are in the edition your job works to.

See your own report rebuilt.

Book a 30-minute demo on one of your real reports.

Not ready to talk? The calculator works out hours and costs back from your own numbers.