Code
ISO 17640: ultrasonic testing of welds: techniques, testing levels, and assessment.
The international standard for how a manual ultrasonic test of a weld is done, from the reference block to the sizing of each indication, with acceptance left to ISO 11666.
What it covers
ISO 17640 in plain terms.
ISO 17640 sets how a manual ultrasonic test of a weld is done: the probes, the reference blocks, how sensitivity is set, how much of the weld is scanned, and how an indication is located and sized. It covers full-penetration welds in ferritic steel from a minimum thickness, and other metals with low attenuation when the parties agree.
It works in four testing levels, A to D. Testing level A asks the least of the scan and testing level C the most; testing level D is for special applications and is agreed case by case. The higher the ISO 5817 quality level the design names, the higher the testing level, and the higher the testing level, the more probe angles, scanning surfaces, and scan directions the weld gets, including scans for transverse imperfections.
Sensitivity is set by one of four techniques: a distance-amplitude curve from side-drilled holes, the DGS method, a rectangular notch for thin welds, or a tandem setup with a flat-bottom hole. Each gives a reference level. Every echo is measured against it, with a transfer correction when the test surface differs from the reference block.
ISO 17640 does not say what passes. The acceptance standard, normally ISO 11666, sets the evaluation, recording, and acceptance levels. ISO 17640 is written so the two fit together, and the application standard or the contract can name another acceptance standard instead.
Regulation
In Europe the standard is EN ISO 17640, and it is the ultrasonic technique that EN 1090-2 for steel structures and the EN pressure equipment standards call up for welds.
- Full title
- Non-destructive testing of welds — Ultrasonic testing — Techniques, testing levels, and assessment
- Issued by
- ISO, adopted in Europe as EN ISO 17640
- Current edition
- ISO 17640:2018
- Applies to
- Manual pulse-echo testing of full-penetration welds in ferritic steel from a minimum thickness, and other low-attenuation metals by agreement
- Testing levels
- A, B, C, and D, with D for special applications agreed between the parties
- Acceptance standard
- ISO 11666, unless the application standard names another
- Linked to
- ISO 5817 quality levels, which set the testing level
- Personnel
- ISO 9712 UT Level II, or an equivalent scheme
Who it's for
One record. Both sides of the job.
How inspection works
Methods under ISO 17640.
Who sets the procedure, who sets acceptance, and who may do the work, method by method.
| Method | Procedure | Acceptance | Certification |
|---|---|---|---|
| Ultrasonic (UT) | ISO 17640 at testing level A, B, C, or D | ISO 11666, or the acceptance standard the application standard names | ISO 9712 UT Level II |
Acceptance criteria
How a weld passes or fails.
ISO 17640 makes the scan valid; the acceptance standard, normally ISO 11666, decides what passes.
- The testing level is set before the scan, from the quality level or the application standard, and it fixes the probes, surfaces, and directions.
- Reference blocks are of the same material and heat treatment as the weld, or close enough that the difference is measured and corrected.
- The sensitivity technique is chosen to match the acceptance standard, because each acceptance level is written for a particular reference reflector.
- The whole weld volume and the heat-affected zone are covered, and the parent metal on the scanning paths is checked first for laminations that would block the beam.
- Each indication is located in the weld, its maximum echo is recorded against the reference level, and its length is measured by the drop technique at the level the acceptance standard sets.
- A transfer correction is measured between the reference block and the test surface and applied before any amplitude is judged.
Where the contract asks for it, an indication is characterized before the call is made, and the characterization follows its own standard, not ISO 17640.
A summary, not the code. Limits and exceptions are in the edition your job works to.
The report
What ISO 17640 reports have to carry.
The fields a Level III checks before signing. Miss one and the report comes back.
- Weld and component ID, material, thickness, and joint geometry
- ISO 17640 testing level, and the ISO 5817 quality level it was chosen from
- Instrument, probes with angle, frequency, and size, and couplant
- Reference block, sensitivity technique, reference level, and transfer correction
- Scanning surfaces, directions, and coverage, including transverse scans where the level requires them
- Each recorded indication: position along the weld, depth, length, and maximum amplitude against the reference level
- Acceptance standard and acceptance level applied, with the result per indication and per weld
- Operator name, ISO 9712 certification, and date
Standards logic
Checked at capture, not after the report.
Where Weld Done holds a code's acceptance limits, each RT, VT, and UT indication is checked against them as it's entered. A rejected one shows the clause, the value, and the limit.
Standards logic →Where reports go wrong
The ISO 17640 mistakes that send a report back.
How the job's procedures come from your plan
The NDT reporting checklist: eight ways to get reports right the first time
No testing level stated.
Without it, nobody can tell whether the weld got the probe angles and surfaces its quality level required.
Sensitivity technique mismatched to the acceptance standard.
An acceptance level written for a side-drilled hole reference does not apply to a scan set up on a flat-bottom hole. The report has to show which technique set the reference level.
Transfer correction skipped.
A rough or painted test surface loses signal against the reference block. Without the correction, every amplitude on the report reads low and indications pass that should not.
Parent metal not checked.
A lamination in the scanning path hides the weld behind it. The report has to show the parent metal was scanned before the weld was.
Related codes
The codes around it.
Edition referenced: ISO 17640:2018. All codes and standards
FAQ
Questions.
Every other answer is on the FAQ page.
What are ISO 17640 testing levels?
Four levels, A to D. Testing level A is the least demanding and testing level C the most; testing level D is for special applications agreed between the parties. A higher level means more probe angles, scanning surfaces, and scan directions.
Does ISO 17640 set acceptance criteria?
No. It sets how the test is done and how indications are sized. Acceptance comes from ISO 11666 or the acceptance standard the application standard names.
How does ISO 17640 relate to ISO 5817?
ISO 5817 sets the quality level of the weld. The quality level sets the ISO 17640 testing level, and through ISO 11666 the acceptance level for what the scan finds.
What is the ISO 17640 equivalent of ASME Section V Article 4?
Both set how welds are tested by ultrasound. ISO 17640 is written around testing levels and a reference level from a named technique; Article 4 is written around a distance-amplitude curve and the referencing construction code sets acceptance.

See your own report rebuilt.
Book a 30-minute demo on one of your real reports.
Not ready to talk? The calculator works out hours and costs back from your own numbers.