Code

ISO 11666: acceptance levels for ultrasonic testing of welds.

The international standard that decides whether an ultrasonic indication in a steel weld is acceptable, at one of two acceptance levels tied to ISO 5817.

Non-destructive testing of welds — Ultrasonic testing — Acceptance levels · ISO · ISO 11666:2018

What it covers

ISO 11666 in plain terms.

ISO 11666 is the acceptance half of ultrasonic testing on welds. ISO 17640 finds and sizes the indications; ISO 11666 decides which ones the weld can keep. It covers full-penetration welds in ferritic steel across a range of thicknesses, tested by manual pulse-echo.

It has two acceptance levels. Acceptance level 2 goes with ISO 5817 quality level B and acceptance level 3 with quality level C. There is no ultrasonic acceptance level for quality level D, so a weld built to quality level D is not normally judged by ultrasound under ISO 11666.

Every indication is judged by its echo amplitude against the reference level set under ISO 17640, and by its length along the weld. The standard sets an evaluation level, a recording level, and an acceptance level, each a number of decibels from the reference level, and the length limits change with weld thickness. Indications under the evaluation level are ignored.

The acceptance levels are written for the four sensitivity techniques of ISO 17640, so the technique that set the reference level has to be on the report. Where the contract asks for it, an indication is characterized to its own standard before the call is made, and an indication judged to be planar is treated more strictly than a volumetric one of the same length.

Full title
Non-destructive testing of welds — Ultrasonic testing — Acceptance levels
Issued by
ISO, adopted in Europe as EN ISO 11666
Current edition
ISO 11666:2018
Applies to
Full-penetration welds in ferritic steel across a range of thicknesses, tested by manual pulse-echo to ISO 17640
Acceptance levels
2 and 3, with acceptance level 2 the stricter
Linked to
ISO 5817 quality level B for acceptance level 2 and quality level C for acceptance level 3
Technique standard
ISO 17640
Judged by
Echo amplitude against the reference level, and length along the weld

Who it's for

One record. Both sides of the job.

How inspection works

Methods under ISO 11666.

Who sets the procedure, who sets acceptance, and who may do the work, method by method.

MethodProcedureAcceptanceCertification
Ultrasonic (UT)ISO 17640ISO 11666 at acceptance level 2 or 3ISO 9712 UT Level II

Acceptance criteria

How a weld passes or fails.

Each indication is placed against the reference level by amplitude, measured for length, and judged against the limits for the acceptance level.

  • Indications below the evaluation level are not evaluated at all.
  • Indications above the recording level are recorded with their position, depth, length, and maximum amplitude.
  • The acceptance level sets how far above the reference level an echo may rise, and the allowable length falls as the amplitude rises.
  • Acceptance level 2 is the stricter; acceptance level 3 allows longer and louder indications for the same thickness.
  • Indications close together along the weld are grouped and judged as one.
  • A weld with an unacceptable indication is repaired and retested, or the indication is characterized where the contract allows it.

The report has to state the acceptance level and the sensitivity technique, because the same echo can pass at acceptance level 3 and fail at acceptance level 2, and the limits only mean something against the reference they were written for.

A summary, not the code. Limits and exceptions are in the edition your job works to.

The report

What ISO 11666 reports have to carry.

The fields a Level III checks before signing. Miss one and the report comes back.

  • Weld and component ID, material, and thickness
  • ISO 5817 quality level and the ISO 11666 acceptance level applied
  • Reference to the ISO 17640 test record and its testing level
  • Sensitivity technique, reference level, and transfer correction
  • Each recorded indication: position along the weld, depth, length, and maximum amplitude against the reference level
  • Characterization result, where one was required
  • Accept or reject per indication and per weld, with repairs and retest
  • Operator name, ISO 9712 certification, and date

How Weld Done builds your NDT report template

Standards logic

Checked at capture, not after the report.

Where Weld Done holds a code's acceptance limits, each RT, VT, and UT indication is checked against them as it's entered. A rejected one shows the clause, the value, and the limit.

Standards logic →
  1. No acceptance level stated.

    Without it, an ultrasonic call cannot be checked against what the design asked for.

  2. Acceptance level read off the wrong technique.

    The limits are written for a named reference reflector. A scan set up on a notch judged against the side-drilled hole limits is wrong in both directions.

  3. Length not measured.

    Acceptance is by amplitude and length together. An indication recorded by amplitude alone cannot be judged.

  4. Quality level D tested to ISO 11666.

    There is no ultrasonic acceptance level for quality level D. The application standard has to say what to do, and the report has to say which standard it used.

Related codes

The codes around it.

Edition referenced: ISO 11666:2018. All codes and standards

FAQ

Questions.

Every other answer is on the FAQ page.

Visit FAQ
What are ISO 11666 acceptance levels?

Two levels. Acceptance level 2 matches ISO 5817 quality level B and acceptance level 3 matches quality level C. Acceptance level 2 is the stricter.

Why is there no acceptance level for quality level D?

ISO 11666 gives no ultrasonic acceptance level for quality level D. Welds at that level are normally judged by other methods, or the application standard sets its own rule.

How does ISO 11666 relate to ISO 17640?

ISO 17640 sets how the ultrasonic test is done and how indications are located and sized. ISO 11666 sets which of those indications are acceptable.

What is the evaluation level in ISO 11666?

The amplitude below which an indication is not evaluated. Above it, the recording level says what goes on the report and the acceptance level says what fails.

See your own report rebuilt.

Book a 30-minute demo on one of your real reports.

Not ready to talk? The calculator works out hours and costs back from your own numbers.