Code
ISO 9934-1: the general principles of magnetic particle testing.
The international standard for magnetic particle testing of ferromagnetic materials, whatever the part: how to magnetize, what field to reach, how to apply and view the particles, and what to record. Welds have their own standard in ISO 17638.
What it covers
ISO 9934-1 in plain terms.
ISO 9934-1 is the base standard for magnetic particle testing. It says how a ferromagnetic part is prepared, magnetized, covered with particles, viewed and recorded, so that a crack or lap at or just under the surface shows as an indication. It applies to any part; the product standards then add what is specific to welds, forgings or castings.
The core rule is the field. Flaws show when they lie across the magnetic flux, so each area is tested in two directions at roughly right angles, and the tangential field strength at the surface has to reach the range the standard sets, verified with a meter or a flux indicator. The standard lists the magnetization techniques and the current types each can use.
It covers both detection media and ties viewing to ISO 3059: fluorescent particles need a minimum UV-A irradiance and low ambient light, color contrast particles a minimum white light level. Part 2 sets what the particles themselves must meet and Part 3 what the equipment must.
It closes with demagnetization, cleaning, and the test report. ISO 17638 applies the same principles to welds and adds the weld-specific overlap and area rules; acceptance always comes from a separate standard.
- Full title
- Non-destructive testing — Magnetic particle testing — Part 1: General principles
- Issued by
- ISO, adopted in Europe as EN ISO 9934-1
- Applies to
- Ferromagnetic materials in any form: castings, forgings, machined parts, tubes, and welds
- Other parts
- ISO 9934-2 covers detection media; ISO 9934-3 covers equipment
- Techniques
- Yoke, current flow, prods, coil, threading bar, and induced current
- Viewing
- Fluorescent particles under UV-A, or color contrast in white light, to ISO 3059
- Acceptance comes from
- The product standard: ISO 23278 for welds, EN 10228-1 for forgings, EN 1369 for castings
- Personnel
- Certified to ISO 9712 for magnetic particle testing
Who it's for
One record. Both sides of the job.
How inspection works
Methods under ISO 9934-1.
Who sets the procedure, who sets acceptance, and who may do the work, method by method.
| Method | Procedure | Acceptance | Certification |
|---|---|---|---|
| Magnetic particle (MT), yoke | ISO 9934-1, with ISO 17638 on welds | The product standard: ISO 23278 for welds | ISO 9712 MT Level II |
| Magnetic particle (MT), current flow or prods | ISO 9934-1 | The product standard at the level named | ISO 9712 MT Level II |
| Magnetic particle (MT), coil or threading bar | ISO 9934-1 | The product standard at the level named | ISO 9712 MT Level II |
Acceptance criteria
How a weld passes or fails.
ISO 9934-1 makes the test valid. The product standard then decides which indications are acceptable.
- The tangential field strength at the surface has to be within the range the standard sets, checked with a meter or a flux indicator and recorded.
- Each area is tested twice, with the field turned roughly ninety degrees between the two, unless a technique proves full coverage in one pass.
- Viewing conditions follow ISO 3059: a minimum UV-A irradiance and a low ambient light level for fluorescent particles, a minimum white light level for color contrast.
- The surface has to be clean and in the condition the procedure names; paint or scale thicker than the procedure allows hides indications.
- Indications are recorded, then judged to the product standard: ISO 23278 for welds, EN 10228-1 for steel forgings, EN 1369 for castings.
A summary, not the code. Limits and exceptions are in the edition your job works to.
The report
What ISO 9934-1 reports have to carry.
The fields a Level III checks before signing. Miss one and the report comes back.
- Part or weld ID, material, and surface condition
- Technique: yoke, prods, current flow, coil, or threading bar, and the current type
- Field strength check and how it was verified
- Detection media: fluorescent or color contrast, and the viewing conditions
- Product standard and acceptance level applied
- Each indication: type, location, and length, and the call
- Demagnetization where required
- Operator name, ISO 9712 certification, and date
Where reports go wrong
The ISO 9934-1 mistakes that send a report back.
How the job's procedures come from your plan
The NDT reporting checklist: eight ways to get reports right the first time
One direction only.
A crack that lies along the field doesn't show. Testing in one direction can pass a cracked part.
No field check on record.
Without a verified field strength, a clean result proves nothing.
Judged to the base standard.
ISO 9934-1 has no acceptance limits. A report that cites it alone has no accept or reject basis; the product standard and its level have to be on the record.
FAQ
Questions.
Every other answer is on the FAQ page.
What does ISO 9934-1 cover?
The general principles of magnetic particle testing on any ferromagnetic part: surface preparation, magnetization techniques, field strength, detection media, viewing conditions, demagnetization, and the report.
What is the difference between ISO 9934-1 and ISO 17638?
ISO 9934-1 is the base standard for any part. ISO 17638 applies it to welds and adds the weld-specific rules. A weld procedure usually cites both, with ISO 23278 for acceptance.
Does ISO 9934-1 have acceptance criteria?
No. It makes the test valid. Acceptance comes from the product standard, such as ISO 23278 for welds or EN 10228-1 for forgings.

See your own report rebuilt.
Book a 30-minute demo on one of your real reports.
Not ready to talk? The calculator works out hours and costs back from your own numbers.