Code
AWS D1.1: the structural steel welding code.
The code for welding structural steel in the US: buildings, industrial structures and fabricated steelwork, from the welding procedure to the final inspection.
What it covers
AWS D1.1 in plain terms.
AWS D1.1 covers welding of structural steel from design of the welded connection, through qualifying the welding procedure and the welder, to fabrication and inspection. Bridges have their own code, AWS D1.5.
A large part of the code is prequalified procedures: joint designs and welding conditions that can be used without testing, as long as every limit is kept. Anything outside those limits has to be qualified by test.
The code separates statically loaded connections, like most buildings, from cyclically loaded ones, like crane girders, and the acceptance criteria differ between them. A report that doesn't say which one it used can't be checked.
In the 2020 edition, inspection is Clause 8. It covers the inspector's duties, visual inspection of every weld, and the radiographic and ultrasonic testing the contract documents call for.
Where it’s used: Construction and infrastructure
In the glossary: CWI · WPS / PQR
Regulation
Building codes in the US adopt the AISC specification for structural steel buildings, which calls for welding to AWS D1.1. Project specifications usually add the inspection extent and any extra criteria.
- Full title
- Structural Welding Code — Steel
- Issued by
- American Welding Society (AWS)
- Edition
- 2020 edition, the one Weld Done holds data for
- Applies to
- Welded structural carbon and low-alloy steel, statically and cyclically loaded, including tubular structures
- Required by
- Building codes, through the AISC steel specification, and project specifications
- Inspection
- Clause 8: visual inspection of every weld, and nondestructive testing where the contract calls for it
- Certification
- AWS CWI for visual; SNT-TC-1A, CP-189, or ISO 9712 for nondestructive testing
- Related codes
- AWS D1.5 for bridges · CSA W59 in Canada
Who it's for
One record. Both sides of the job.
How inspection works
Methods under AWS D1.1.
Who sets the procedure, who sets acceptance, and who may do the work, method by method.
| Method | Procedure | Acceptance | Certification |
|---|---|---|---|
| Visual (VT) | AWS D1.1 Clause 8, every weld | Clause 8 visual acceptance table, by connection type | AWS CWI |
| Ultrasonic (UT) | AWS D1.1 Clause 8 ultrasonic procedure | Clause 8 ultrasonic acceptance tables, statically or cyclically loaded | SNT-TC-1A, CP-189, or ISO 9712 Level II |
| Radiographic (RT) | AWS D1.1 Clause 8 radiographic procedure | Clause 8 radiographic acceptance criteria | SNT-TC-1A, CP-189, or ISO 9712 Level II |
| Magnetic particle (MT) | Per ASTM E709, as Clause 8 directs | Clause 8 criteria for the connection type | SNT-TC-1A, CP-189, or ISO 9712 Level II |
| Penetrant (PT) | Per ASTM E165, as Clause 8 directs | Clause 8 criteria for the connection type | SNT-TC-1A, CP-189, or ISO 9712 Level II |
Acceptance criteria
How a weld passes or fails.
D1.1 acceptance depends on two things before the flaw itself: the method, and whether the connection is statically or cyclically loaded. Cyclically loaded connections get tighter limits.
- Visual: cracks reject; the table then limits incomplete fusion, crater fill, weld profile and size, undercut, and piping porosity, each by connection type.
- Undercut is limited by depth, and by length for deeper undercut. Cyclically loaded members subject to tension get stricter limits.
- Ultrasonic: each indication is rated in decibels against a reference reflector, corrected for distance, and graded from Class A, which rejects, to Class D, which is minor. Length limits apply by class.
- Radiographic: elongated and rounded indications are limited by size and spacing, against the weld size.
- Welds that fail are repaired to a qualified procedure and inspected again by the same method.
Contract documents can add to these criteria or call for testing the code doesn't require. The engineer's specification is part of the acceptance standard on every job.
A summary, not the code. Limits and exceptions are in the edition your job works to.
The report
What AWS D1.1 reports have to carry.
The fields a Level III checks before signing. Miss one and the report comes back.
- Project, client, drawing, member, and joint ID
- Welding procedure (prequalified or qualified) and welder ID
- Material, thickness, and joint type
- AWS D1.1 edition, and statically or cyclically loaded
- Method and technique; for UT, the transducer, angle, reference level and scanning pattern
- Each indication: rating or size, location, length, class, and the accept or reject call
- Disposition per weld, and repair and re-inspection
- Technician name, certification (CWI or NDT level), signature and date
Standards logic
Checked at capture, not after the report.
Where Weld Done holds a code's acceptance limits, each RT, VT, and UT indication is checked against them as it's entered. A rejected one shows the clause, the value, and the limit.
Standards logic →Where reports go wrong
The AWS D1.1 mistakes that send a report back.
How the job's procedures come from your plan
The NDT reporting checklist: eight ways to get reports right the first time
D1.1 on a pipeline job.
A tech who works structural most days picks D1.1 on an API job. The acceptance criteria are different, so the calls are wrong even when the inspection was done right.
The wrong loading criteria.
A cyclically loaded member called against statically loaded limits lets through flaws the code would reject.
UT without the rating math.
A D1.1 UT report that gives a class without the decibel values behind it can't be checked by a Level III.
Bridge steel to the building code.
Highway bridges are welded and inspected to AWS D1.5, not D1.1.
Related codes
The codes around it.
From the blog: AWS D1.1 inspection moved to Clause 8 · NDT methods for steel bridges
Edition referenced: AWS D1.1/D1.1M:2020. All codes and standards
FAQ
Questions.
Every other answer is on the FAQ page.
What are the AWS D1.1 visual inspection acceptance criteria?
In the 2020 edition they're in a table in Clause 8. Cracks reject; the table then limits incomplete fusion, crater fill, weld size and profile, undercut, and porosity, with different limits for statically and cyclically loaded connections.
Which clause covers inspection in AWS D1.1?
Clause 8 in the 2020 edition. Earlier editions put inspection in Clause 6, so check which edition a job works to.
How are UT indications rated under AWS D1.1?
Each indication is rated in decibels against a reference reflector, corrected for sound path distance, then graded by class. Class A rejects; lower classes are limited by length.
Does AWS D1.1 cover bridges?
No. Steel highway bridges are welded and inspected to AWS D1.5, the Bridge Welding Code.

See your own report rebuilt.
Book a 30-minute demo on one of your real reports.
Not ready to talk? The calculator works out hours and costs back from your own numbers.